Your browser doesn't support javascript.
loading
Ultrasound-Vortex-Assisted Dispersive Liquid-Liquid Microextraction Combined with High Performance Liquid Chromatography-Diode Array Detection for Determining UV Filters in Cosmetics and the Human Stratum Corneum.
Liao, Fang-Yi; Su, Yu-Lin; Weng, Jing-Ru; Lin, Ying-Chi; Feng, Chia-Hsien.
Afiliação
  • Liao FY; School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
  • Su YL; Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
  • Weng JR; Department of Marine Biotechnology and Resources, National Sun Yat-sen University, Kaohsiung 80424, Taiwan.
  • Lin YC; School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
  • Feng CH; The Ph.D. Program in Toxicology, College of Pharmacy, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
Molecules ; 25(20)2020 Oct 12.
Article em En | MEDLINE | ID: mdl-33053784
ABSTRACT
This study explores the amounts of common chemical ultraviolet (UV) filters (i.e., avobenzone, bemotrizinol, ethylhexyl triazone, octocrylene, and octyl methoxycinnamate) in cosmetics and the human stratum corneum. An ultrasound-vortex-assisted dispersive liquid-liquid microextraction (US-VA-DLLME) method with a high-performance liquid chromatography-diode array detector was used to analyze UV filters. A bio-derived solvent (i.e., anisole) was used as the extractant in the US-VA-DLLME procedure, along with methanol as the dispersant, a vortexing time of 4 min, and ultrasonication for 3 min. The mass-transfer rate of the extraction process was enhanced due to vortex-ultrasound combination. Various C18 end-capped columns were used to investigate the separation characteristics of the UV filters, with XBridge BEH or CORTECS selected as the separation column. Calibration curves were constructed in the 0.05-5 µg/mL (all filters except octocrylene) and 0.1-10 µg/mL (octocrylene) ranges, and excellent analytical linearities with coefficients of determination (r2) above 0.998. The developed method was successfully used to analyze sunscreen. Moreover, experiments were designed to simulate the sunscreen-usage habits of consumers, and the cup method was used to extract UV filters from the human stratum corneum. The results suggest that a makeup remover should be employed to remove water-in-oil sunscreens from skin.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cosméticos / Epiderme / Microextração em Fase Líquida / Ondas Ultrassônicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cosméticos / Epiderme / Microextração em Fase Líquida / Ondas Ultrassônicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Taiwan