Your browser doesn't support javascript.
loading
Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes.
Labate, Luca; Palla, Daniele; Panetta, Daniele; Avella, Federico; Baffigi, Federica; Brandi, Fernando; Di Martino, Fabio; Fulgentini, Lorenzo; Giulietti, Antonio; Köster, Petra; Terzani, Davide; Tomassini, Paolo; Traino, Claudio; Gizzi, Leonida A.
Afiliação
  • Labate L; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy. luca.labate@ino.cnr.it.
  • Palla D; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Panetta D; Consiglio Nazionale delle Ricerche, Istituto di Fisiologia Clinica, Pisa, Italy.
  • Avella F; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Baffigi F; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Brandi F; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Di Martino F; Unità Operativa di Fisica Sanitaria, Azienza Ospedaliero-Universitaria Pisana, Pisa, Italy.
  • Fulgentini L; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Giulietti A; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Köster P; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Terzani D; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Tomassini P; Lawrence Berkeley National Laboratory, LBL, Berkeley, CA, USA.
  • Traino C; Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica, Pisa, Italy.
  • Gizzi LA; Unità Operativa di Fisica Sanitaria, Azienza Ospedaliero-Universitaria Pisana, Pisa, Italy.
Sci Rep ; 10(1): 17307, 2020 10 14.
Article em En | MEDLINE | ID: mdl-33057078
ABSTRACT
Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dosagem Radioterapêutica / Elétrons / Radioterapia de Intensidade Modulada / Lasers Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dosagem Radioterapêutica / Elétrons / Radioterapia de Intensidade Modulada / Lasers Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália