High-Resolution Gadolinium-Enhanced MR Cisternography Using Compressed-Sensing T1 SPACE Technique for Detection of Intracranial CSF Leaks.
Duman, I E; Demerath, T; Stadler, A; Elsheikh, S; Raithel, E; Forman, C; Hildenbrand, T; Shah, M; Grauvogel, J; Scheiwe, C; Urbach, H; Meckel, S.
Afiliação
  • Duman IE; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.) edda_ikram@hotmail.com.
  • Demerath T; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.).
  • Stadler A; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.).
  • Elsheikh S; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.).
  • Raithel E; Siemens Healthcare GmbH (E.R., C.F.), Erlangen, Germany.
  • Forman C; Siemens Healthcare GmbH (E.R., C.F.), Erlangen, Germany.
  • Hildenbrand T; Otorhinolaryngology (T.H.).
  • Shah M; Neurosurgery (M.S., J.G., C.S.), University of Freiburg Medical Center, Faculty of Medicine, University of Freiburg, Freiberg, Germany.
  • Grauvogel J; Neurosurgery (M.S., J.G., C.S.), University of Freiburg Medical Center, Faculty of Medicine, University of Freiburg, Freiberg, Germany.
  • Scheiwe C; Neurosurgery (M.S., J.G., C.S.), University of Freiburg Medical Center, Faculty of Medicine, University of Freiburg, Freiberg, Germany.
  • Urbach H; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.).
  • Meckel S; From the Departments of Neuroradiology (I.E.D., T.D., A.S., S.E., H.U., S.M.).
AJNR Am J Neuroradiol ; 42(1): 116-118, 2021 01.
Article em En | MEDLINE | ID: mdl-33122210
ABSTRACT
In patients with CSF rhinorrhea, accurate identification of the CSF leakage site is crucial for surgical planning. We describe the application of a novel gadolinium-enhanced high-resolution 3D compressed-sensing T1 SPACE technique for MR cisternography and compare findings with CT cisternography and intraoperative results. In our pilot experience with 7 patients, precise detection of CSF leaks was feasible using compressed-sensing T1 SPACE, which appeared to be superior to CT cisternography.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Rinorreia de Líquido Cefalorraquidiano / Neuroimagem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Rinorreia de Líquido Cefalorraquidiano / Neuroimagem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2021 Tipo de documento: Article