Your browser doesn't support javascript.
loading
Application of temperature-controlled ultrasound treatment and its potential to reduce phosphate content in frankfurter-type sausages by 50.
Zhang, Fengxue; Zhao, Honglei; Cao, Chuanai; Kong, Baohua; Xia, Xiufang; Liu, Qian.
Afiliação
  • Zhang F; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China.
  • Zhao H; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China.
  • Cao C; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China.
  • Kong B; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China.
  • Xia X; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China.
  • Liu Q; College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang 150030, China; Heilongjiang Green Food Science & Research Institute, Harbin, Heilongjiang 150028, China. Electronic address: liuqian@neau.edu.cn.
Ultrason Sonochem ; 71: 105379, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33157359
ABSTRACT
The objective of this study was to evaluate the effect of ultrasound treatments with different durations (15, 20, 25, 30, and 35 min) at a low static temperature (12 °C) controlled by an intelligent temperature control and monitoring system on the quality of 50% reduced-phosphate frankfurters. The results show that without ultrasound treatment, phosphate reduction caused some obvious deficits in the textural properties, sensorial parameters, and oxidative stability of frankfurters. Moreover, 25-min ultrasound treatment could significantly lower the cooking loss and enhance emulsion stability, textural properties, and sensorial parameters of reduced phosphate frankfurters, which was also verified by dynamic water distribution analysis and microstructural observation. Additionally, low constant temperature during ultrasound treatment was another crucial factor in retarding lipid oxidation during storage. Therefore, ultrasound treatment with moderate duration and stable low temperature could be considered a successful approach to obtain healthier reduced-phosphate frankfurters under the "clean label" concept.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatos / Temperatura / Ondas Ultrassônicas / Produtos da Carne Idioma: En Revista: Ultrason Sonochem Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatos / Temperatura / Ondas Ultrassônicas / Produtos da Carne Idioma: En Revista: Ultrason Sonochem Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China
...