Your browser doesn't support javascript.
loading
ATR-FTIR spectroscopy in blood plasma combined with multivariate analysis to detect HIV infection in pregnant women.
Silva, Lidiane G; Péres, Ana F S; Freitas, Daniel L D; Morais, Camilo L M; Martin, Francis L; Crispim, Janaina C O; Lima, Kassio M G.
Afiliação
  • Silva LG; Institute of Chemistry, Biological Chemistry and Chemometrics, Federal University of Rio Grande Do Norte, Natal, RN, 5072-970, Brazil.
  • Péres AFS; Department of Clinical and Toxicological Analysis, Federal University of Rio Grande Do Norte, Natal, RN, 59072-970, Brazil.
  • Freitas DLD; Maternity School Januário Cicco, Federal University of Rio Grande Do Norte, Natal, RN, 59072-970, Brazil.
  • Morais CLM; Institute of Chemistry, Biological Chemistry and Chemometrics, Federal University of Rio Grande Do Norte, Natal, RN, 5072-970, Brazil.
  • Martin FL; School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
  • Crispim JCO; Biocel Ltd, Hull, HU10 7TS, UK.
  • Lima KMG; Department of Clinical and Toxicological Analysis, Federal University of Rio Grande Do Norte, Natal, RN, 59072-970, Brazil.
Sci Rep ; 10(1): 20156, 2020 11 19.
Article em En | MEDLINE | ID: mdl-33214678
ABSTRACT
The primary concern for HIV-infected pregnant women is the vertical transmission that can occur during pregnancy, in the intrauterine period, during labour or even breastfeeding. The risk of vertical transmission can be reduced by early diagnosis. Therefore, it is necessary to develop new methods to detect this virus in a quick and low-cost fashion, as colorimetric assays for HIV detection tend to be laborious and costly. Herein, attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy combined with multivariate analysis was employed to distinguish HIV-infected patients from healthy uninfected controls in a total of 120 blood plasma samples. The best sensitivity (83%) and specificity (92%) values were obtained using the genetic algorithm with linear discriminant analysis (GA-LDA). These good classification results in addition to the potential for high analytical frequency, the low cost and reagent-free nature of this method demonstrate its potential as an alternative tool for HIV screening during pregnancy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Infecciosas na Gravidez / Infecções por HIV / Espectroscopia de Infravermelho com Transformada de Fourier Tipo de estudo: Screening_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Infecciosas na Gravidez / Infecções por HIV / Espectroscopia de Infravermelho com Transformada de Fourier Tipo de estudo: Screening_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil