A novel approach for obtaining 12-lead electrocardiograms in horses.
Hesselkilde, Eva M; Isaksen, Jonas L; Petersen, Bettina V; Carstensen, Helena; Jespersen, Thomas; Pehrson, Steen; Kanters, Jørgen K; Buhl, Rikke.
Afiliação
  • Hesselkilde EM; Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Taastrup, Denmark.
  • Isaksen JL; Laboratory of Experimental Cardiology, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen N, Denmark.
  • Petersen BV; Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Taastrup, Denmark.
  • Carstensen H; Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Taastrup, Denmark.
  • Jespersen T; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen N, Denmark.
  • Pehrson S; Department of Cardiology, The Heart Centre, Copenhagen University Hospital, Copenhagen Ø, Denmark.
  • Kanters JK; Laboratory of Experimental Cardiology, Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen N, Denmark.
  • Buhl R; Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Taastrup, Denmark.
J Vet Intern Med ; 35(1): 521-531, 2021 Jan.
Article em En | MEDLINE | ID: mdl-33274799
ABSTRACT

BACKGROUND:

In equine medicine, 12-lead electrocardiograms (ECGs) rarely are used, which may in part be a result of shortcomings in the existing guidelines for obtaining 12-lead ECGs in horses. The guidelines recommend placing the limb leads on the extremities, which is inappropriate because the ventricular mean electrical axis is then perpendicular to the limb leads, leading to large variations in ECG configuration even among healthy horses. From an electrophysiological point of view, the leads instead should be parallel to the electrical axis to minimize variability.

OBJECTIVE:

Develop an improved method for obtaining 12-lead ECGs in horses based on electrophysiology and cardiac electrical vectors relevant to horses. ANIMALS Thirty-five healthy Standardbred horses.

METHODS:

Two ECGs obtained at rest; 1 ECG with the electrodes placed according to the method developed in the present study, the Copenhagen method, and 1 ECG following existing guidelines.

RESULTS:

In the Copenhagen method, we repositioned the limb electrodes to the thorax to better capture the electrical activity of the heart. Variation in the mean electrical axis decreased dramatically with the Copenhagen method (SD decreased from 24.6° to 1.6°, P < .001). Consequently, this new method provided stable ECGs with repeatable configurations. CONCLUSIONS AND CLINICAL IMPORTANCE With this novel method, the ECG is recorded with respect to the electric axis to fully realize the potential of 12-lead ECG in horses. The Copenhagen method delivered more consistent and reliable ECG recordings compared to existing guidelines. The Copenhagen method potentially allows for expanded use of 12-lead ECGs in equine medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia / Coração Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: J Vet Intern Med Assunto da revista: MEDICINA INTERNA / MEDICINA VETERINARIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia / Coração Tipo de estudo: Guideline Limite: Animals Idioma: En Revista: J Vet Intern Med Assunto da revista: MEDICINA INTERNA / MEDICINA VETERINARIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca