Your browser doesn't support javascript.
loading
Comprehensive In Silico Evaluation of Accessory Rod Position, Rod Material and Diameter, Use of Cross-connectors, and Anterior Column Support in a Pedicle Subtraction Osteotomy Model: Part II: Effects on Lumbosacral Rod and Screw Strain.
Jazini, Ehsan; Gelb, Daniel E; Tareen, Jarid; Ludwig, Steven C; Harris, Jonathan A; Amin, Dhara B; Wang, Wenhai; Van Horn, Margaret R; Patel, Pavan D; Mirabile, Belin A; Bucklen, Brandon S.
Afiliação
  • Jazini E; Georgetown University Hospital, Department of Orthopedics, Washington DC.
  • Gelb DE; Department of Orthopaedics, University of Maryland School of Medicine, Baltimore, MD.
  • Tareen J; Department of Orthopaedics, University of Maryland School of Medicine, Baltimore, MD.
  • Ludwig SC; Department of Orthopaedics, University of Maryland School of Medicine, Baltimore, MD.
  • Harris JA; Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA.
  • Amin DB; Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA.
  • Wang W; Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA.
  • Van Horn MR; Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA.
  • Patel PD; School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA.
  • Mirabile BA; Department of Mechanical Engineering, College of Engineering, University of Notre Dame, Notre Dame, IN.
  • Bucklen BS; Musculoskeletal Education and Research Center, A Division of Globus Medical, Inc., Audubon, PA.
Spine (Phila Pa 1976) ; 46(1): E12-E22, 2021 Jan 01.
Article em En | MEDLINE | ID: mdl-33315361
ABSTRACT
STUDY

DESIGN:

In silico finite element study.

OBJECTIVE:

The aim of this study was to evaluate effects of six construct factors on rod and screw strain at the lumbosacral junction in an in silico pedicle subtraction osteotomy (PSO) model traditional inline and alternative Ames-Deviren-Gupta (ADG) multi-rod techniques, number of accessory rods (three-rod vs. four-rod), rod material (cobalt-chrome [CoCr] or stainless steel [SS] vs. titanium [Ti]), rod diameter (5.5 vs. 6.35 mm), and use of cross-connectors (CC), or anterior column support (ACS). SUMMARY OF BACKGROUND DATA Implant failure and pseudoarthrosis at the lumbosacral junction following PSO are frequently reported. Clinicians may modulate reconstructs with multiple rods, rod position, rod material, and diameter, and with CC or ACS to reduce mechanical demand. An evaluation of these features' effects on rod and screw strains is lacking.

METHODS:

A finite element model (T12-S1) with intervertebral discs and ligaments was created and validated with cadaveric motion data. Lumbosacral rod and screw strain data were collected for 96 constructs across all six construct factors and normalized to the Ti 2-Rod control.

RESULTS:

The inline technique resulted in 12.5% to 51.3% more rod strain and decreased screw strain (88.3% to 95%) compared to ADG at the lumbosacral junction. An asymmetrical strain distribution was observed in the three-rod inline technique in comparison to four-rod, which was more evenly distributed. Regardless of construct features, rod strain was significantly decreased by rod material (CoCr > SS > Ti), and increasing rod diameter from 5.5 mm to 6.35 mm reduced strain by 9.9% to 22.1%. ACS resulted in significant reduction of rod (37.8%-59.8%) and screw strains (23.2%-65.8%).

CONCLUSION:

Increasing rod diameter, using CoCr rods, and ACS were the most effective methods in reducing rod strain at the lumbosacral junction. The inline technique decreased screw strain and increased rod strain compared to ADG. LEVEL OF EVIDENCE N/A.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteotomia / Coluna Vertebral / Simulação por Computador Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Spine (Phila Pa 1976) Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteotomia / Coluna Vertebral / Simulação por Computador Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Spine (Phila Pa 1976) Ano de publicação: 2021 Tipo de documento: Article