Highly Sensitive Detection of CA 125 Protein with the Use of an n-Type Nanowire Biosensor.
Malsagova, Kristina A; Pleshakova, Tatyana O; Galiullin, Rafael A; Kozlov, Andrey F; Shumov, Ivan D; Popov, Vladimir P; Tikhonenko, Fedor V; Glukhov, Alexander V; Ziborov, Vadim S; Petrov, Oleg F; Fortov, Vladimir E; Archakov, Alexander I; Ivanov, Yuri D.
Afiliação
  • Malsagova KA; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Pleshakova TO; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Galiullin RA; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Kozlov AF; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Shumov ID; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Popov VP; Rzhanov Institute of Semiconductor Physics, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia.
  • Tikhonenko FV; Rzhanov Institute of Semiconductor Physics, Siberian Branch of Russian Academy of Sciences, 630090 Novosibirsk, Russia.
  • Glukhov AV; JSC Novosibirsk Plant of Semiconductor Devices with OKB, 630082 Novosibirsk, Russia.
  • Ziborov VS; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
  • Petrov OF; Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia.
  • Fortov VE; Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia.
  • Archakov AI; Joint Institute for High Temperatures of Russian Academy of Sciences, 125412 Moscow, Russia.
  • Ivanov YD; Laboratory of nanotechnology, Institute of Biomedical Chemistry, 119121 Moscow, Russia.
Biosensors (Basel) ; 10(12)2020 Dec 18.
Article em En | MEDLINE | ID: mdl-33353197
ABSTRACT
The detection of CA 125 protein in a solution using a silicon-on-insulator (SOI)-nanowire biosensor with n-type chip has been experimentally demonstrated. The surface of nanowires was modified by covalent immobilization of antibodies against CA 125 in order to provide the biospecificity of the target protein detection. We have demonstrated that the biosensor signal, which results from the biospecific interaction between CA 125 and the covalently immobilized antibodies, increases with the increase in the protein concentration. At that, the minimum concentration, at which the target protein was detectable with the SOI-nanowire biosensor, amounted to 1.5 × 10-16 M.