Your browser doesn't support javascript.
loading
Defining the iliac wing osseous fixation pathways: anatomy and implant constriction points.
Wang, Miqi; Jacobs, Robert C; Bartlett, Craig S; Schottel, Patrick C.
Afiliação
  • Wang M; Department of Orthopaedics & Rehabilitation, University of Vermont, 4th floor Safford Hall, 95 Carrigan Dr., Burlington, VT, 05405, USA. mimi.wang@gmail.com.
  • Jacobs RC; Department of Orthopaedic Surgery, University of Minnesota, 2450 Riverside Ave South, R200, Minneapolis, MN, 55454, USA.
  • Bartlett CS; Department of Orthopaedics & Rehabilitation, University of Vermont, 4th floor Safford Hall, 95 Carrigan Dr., Burlington, VT, 05405, USA.
  • Schottel PC; Department of Orthopaedics & Rehabilitation, University of Vermont, 4th floor Safford Hall, 95 Carrigan Dr., Burlington, VT, 05405, USA.
Arch Orthop Trauma Surg ; 142(5): 755-761, 2022 May.
Article em En | MEDLINE | ID: mdl-33389023
INTRODUCTION: Insertion of iliac wing implants requires understanding of the curvilinear shape of the ilium. This study serves to quantitatively identify the area of iliac inner-outer table convergence (IOTC), characterize the iliac wing osseous corridor, and define the gluteal pillar osseous corridor. METHODS: Computed tomography scans of 100 male and 100 female hemipelves were evaluated. The iliac wing was studied using manual best-fit analysis of the bounds of the inner and outer cortices. The IOTC was defined as the location of the iliac wing with an intercortical width less than 5 mm. The shortest distance from the apex of the iliac crest to the superior border of the IOTC was defined as the iliac wing osseous corridor. Finally, the width of the gluteal pillar corridor from the gluteus medius tubercle to the ischial tuberosity was measured. RESULTS: The IOTC is an elliptical area measuring 22.3 cm2. All ilia had an area where the inner and outer cortices converged to an intercortical width of less than 5 mm; 48% converged to a single cortex. The shortest mean distance from the superior edge of the iliac crest to the beginning of the IOTC was 20.3 mm in men and 13.8 mm in women (p < 0.001). The gluteal pillar diameter averaged 5.3 mm in men and 4.3 mm in women (p < 0.001). DISCUSSION: All ilia converge to a thin and frequently unicortical central region. A 4.5 mm iliac wing lag screw will not breach the cortex if it remains within 20 mm or 14 mm distal to the cranial aspect of the iliac crest in males and females, respectively. Not only is the gluteal pillar smaller than previously thought, in 41% of males and 73% of females, it is not be large enough for 5 mm implants. CONCLUSION: This study quantitatively assesses the dimensions of the IOTC, the iliac crest osseous corridor, and the gluteal pillar. Overall, our findings provide improved understanding of the limits for implant use in the iliac wing as well as better appreciation of the complex osteology of the ilium. This will help surgeons to identify safe areas for implant placement and avoid inadvertent cortical penetration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Ortopédicos / Ílio Tipo de estudo: Prognostic_studies Limite: Female / Humans / Male Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Ortopédicos / Ílio Tipo de estudo: Prognostic_studies Limite: Female / Humans / Male Idioma: En Revista: Arch Orthop Trauma Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha