Your browser doesn't support javascript.
loading
Measuring stem anteversion after total hip arthroplasty: posterior condylar tangent versus transepicondylar axis.
Castagnini, Francesco; Giardina, Federico; Tassinari, Enrico; Biondi, Federico; Bracci, Giovanni; Traina, Francesco.
Afiliação
  • Castagnini F; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy. francescocastagnini@hotmail.it.
  • Giardina F; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
  • Tassinari E; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
  • Biondi F; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
  • Bracci G; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
  • Traina F; Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d'anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Via Pupilli 1, 40136, Bologna, Italy.
Skeletal Radiol ; 50(9): 1775-1779, 2021 Sep.
Article em En | MEDLINE | ID: mdl-33532940
OBJECTIVE: Stem anteversion in total hip arthroplasty (THA) has been measured using two different distal references, the posterior condyle (PC) or the transepicondylar axis (TEA). The reliability, the difference in value between these two techniques, and the possible confounding factors are scarcely known. Aims of this work were to assess (1) the intraclass correlation and the difference between the two measurement techniques and (2) the possible influence of condylar dysmorphisms on the anteversion value discrepancy. MATERIALS AND METHODS: A consecutive series of post-THA CT scans were selected, excluding hip dysplasia, end-stage knee osteoarthritis, and replaced knees. Using a surgical planning software, stem anteversion was measured using the PC or the TEA reference. The intraclass reliability was assessed. The anteroposterior femoral condyle diameters were measured: the difference and the ratio were measured and correlated with the stem anteversion values. RESULTS: 91 CT scans were included. Inter/intra-observer TEA measurements were more reliable than PC. The intraclass correlation between PC and TEA anteversion measurements was good, 0.954 (CI 95% 0.922-0965). The mean difference between PC and TEA anteversion was 5.27 ± 2.41°. The difference and the ratio between the two anteroposterior condyle diameters did not influence the anteversion difference (respectively, p 0.797 and p 0.901). CONCLUSIONS: TEA and PC demonstrated to achieve a good correlation, not dependent from the condyle morphology. However, the difference between the two measurements (5°) can severely influence the combined anteversion (10-20%): due to clinical applicability and better inter/intra-observer agreement, TEA should be preferred for measuring stem anteversion.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Osteoartrite do Joelho / Luxação do Quadril / Prótese de Quadril Limite: Humans Idioma: En Revista: Skeletal Radiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Osteoartrite do Joelho / Luxação do Quadril / Prótese de Quadril Limite: Humans Idioma: En Revista: Skeletal Radiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha