Your browser doesn't support javascript.
loading
[Establishment of Quantitative SPR Assay for Antibodies Against Human Platelet Antigen-1a].
Li, Rui-Shu; Ni, Ming-Chen; Zhu, Hui-Jun; Ma, Qin-Qin; Fu, Min; Lu, Ping.
Afiliação
  • Li RS; Shanghai Blood Center, Shanghai Institute of Blood Transfusion, Shanghai 200051, China.
  • Ni MC; Department of Laboratory Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
  • Zhu HJ; Shanghai Blood Center, Shanghai Institute of Blood Transfusion, Shanghai 200051, China.
  • Ma QQ; Shanghai Blood Center, Shanghai Institute of Blood Transfusion, Shanghai 200051, China.
  • Fu M; Shanghai Blood Center, Shanghai Institute of Blood Transfusion, Shanghai 200051, China.
  • Lu P; Shanghai Blood Center, Shanghai Institute of Blood Transfusion, Shanghai 200051, China,E-mail: luping@sbc.org.cn.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 29(1): 239-242, 2021 Feb.
Article em Zh | MEDLINE | ID: mdl-33554827
ABSTRACT

OBJECTIVE:

To establish quantitative surface plasmon resonance (SPR) assay for antibodies against human platelet antigen-1a (HPA-1a).

METHODS:

Recombinant protein was fixed on the chip surface by amino coupling method. SPR assay was used to detect the standard antibodies against HPA-1a at different conceatration. The optimal experimental parameters were determined, and standard curves were constructed with linear regression. Moreover, the sensitivity, specificity, accuracy and precision of the assay were evaluated.

RESULTS:

The quantitative SPR assay for HPA-1a antibodies was established. The determination ranges were 0-20 IU, with accuracy (recovery rate) was 97.75%-103.08%. The intra-assay precision [coefficients of variation (CV)] was 3.53%-4.29%, and the inter-assay precision (CV) was 2.08%-4.40%. For specificity test, several kinds of monoclonal and human antibodies against platelet membrane protein were tested and no positive result was observed.

CONCLUSION:

The established quantitative SPR assay for HPA-1a antibodies shows good sensitivity, specificity, accuracy and precision, and this rapid and simple method provides a new reference method for scientific research and clinical antibody detection.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Antígenos de Plaquetas Humanas Limite: Humans Idioma: Zh Revista: Zhongguo Shi Yan Xue Ye Xue Za Zhi Assunto da revista: HEMATOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Antígenos de Plaquetas Humanas Limite: Humans Idioma: Zh Revista: Zhongguo Shi Yan Xue Ye Xue Za Zhi Assunto da revista: HEMATOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China