Your browser doesn't support javascript.
loading
On the Rate Constant for NH2+HO2 and Third-Body Collision Efficiencies for NH2+H(+M) and NH2+NH2(+M).
Glarborg, Peter; Hashemi, Hamid; Cheskis, Sergey; Jasper, Ahren W.
Afiliação
  • Glarborg P; DTU Chemical Engineering, Technical University of Denmark, 2800 Lyngby, Denmark.
  • Hashemi H; DTU Chemical Engineering, Technical University of Denmark, 2800 Lyngby, Denmark.
  • Cheskis S; School of Chemistry, Tel Aviv University, Ramat Aviv, IL-69978 Tel Aviv, Israel.
  • Jasper AW; Chemical Sciences and Engineering Division, Argonne National Laboratory, 9700 S Cass Ave., Argonne, Illinois 60439 United States.
J Phys Chem A ; 125(7): 1505-1516, 2021 Feb 25.
Article em En | MEDLINE | ID: mdl-33560846
In low-temperature flash photolysis of NH3/O2/N2 mixtures, the NH2 consumption rate and the product distribution is controlled by the reactions NH2 + HO2 → products (R1), NH2 + H (+M) → NH3 (+M) (R2), and NH2 + NH2 (+M) → N2H4 (+M) (R3). In the present work, published flash photolysis experiments by, among others, Cheskis and co-workers, are re-interpreted using recent direct measurements of NH2 + H (+N2) and NH2 + NH2 (+N2) from Altinay and Macdonald. To facilitate analysis of the FP data, relative third-body collision efficiencies compared to N2 for R2 and R3 were calculated for O2 and NH3 as well as for other selected molecules. Results were in good agreement with the limited experimental data. Based on reported NH2 decay rates in flash photolysis of NH3/O2/N2, a rate constant for NH2 + HO2 → NH3 + O2 (R1a) of k1a = 1.5(±0.5) × 1014 cm3 mol-1 s-1 at 295 K was derived. This value is higher than earlier determinations based on the FP results but in good agreement with recent theoretical work. Kinetic modeling of reported N2O yields indicates that NH2 + HO2 → H2NO + O (R1c) is competing with R1a, but perturbation experiments with addition of CH4 indicate that it is not a dominating channel. Measured HNO profiles indicate that this component is formed directly by NH2 + HO2 → HNO + H2O (R1b), but theoretical work indicates that R1b is only a minor channel. Based on this analysis, we estimate k1c = 2.5 × 1013 cm3 mol-1 s-1 and k1b = 2.5 × 1012 cm3 mol-1 s-1 at 295 K, with significant uncertainty margins.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Phys Chem A Assunto da revista: QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: Estados Unidos