Your browser doesn't support javascript.
loading
Upgrade of the SPECIES beamline at the MAX IV Laboratory.
Kokkonen, Esko; Lopes da Silva, Felipe; Mikkelã, Mikko Heikki; Johansson, Niclas; Huang, Shih Wen; Lee, Jenn Min; Andersson, Margit; Bartalesi, Antonio; Reinecke, Benjamin N; Handrup, Karsten; Tarawneh, Hamed; Sankari, Rami; Knudsen, Jan; Schnadt, Joachim; Såthe, Conny; Urpelainen, Samuli.
Afiliação
  • Kokkonen E; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Lopes da Silva F; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Mikkelã MH; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Johansson N; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Huang SW; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Lee JM; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Andersson M; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Bartalesi A; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Reinecke BN; Division of Synchrotron Radiation Research, Department of Physics, Lund University, Box 118, 221 00 Lund, Sweden.
  • Handrup K; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Tarawneh H; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Sankari R; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Knudsen J; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Schnadt J; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Såthe C; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
  • Urpelainen S; MAX IV Laboratory, Lund University, Box 118, 221 00 Lund, Sweden.
J Synchrotron Radiat ; 28(Pt 2): 588-601, 2021 Mar 01.
Article em En | MEDLINE | ID: mdl-33650571
ABSTRACT
The SPECIES beamline has been transferred to the new 1.5 GeV storage ring at the MAX IV Laboratory. Several improvements have been made to the beamline and its endstations during the transfer. Together the Ambient Pressure X-ray Photoelectron Spectroscopy and Resonant Inelastic X-ray Scattering endstations are capable of conducting photoelectron spectroscopy in elevated pressure regimes with enhanced time-resolution and flux and X-ray scattering experiments with improved resolution and flux. Both endstations offer a unique capability for experiments at low photon energies in the vacuum ultraviolet and soft X-ray range. In this paper, the upgrades on the endstations and current performance of the beamline are reported.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Synchrotron Radiat Assunto da revista: RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Suécia
...