Your browser doesn't support javascript.
loading
Single-Institutional Experience of Chronic Intracranial Electroencephalography Based on the Combined Usage of Subdural and Depth Electrodes.
Takayama, Yutaro; Ikegaya, Naoki; Iijima, Keiya; Kimura, Yuiko; Yokosako, Suguru; Muraoka, Norihiro; Kosugi, Kenzo; Kaneko, Yuu; Yamamoto, Tetsuya; Iwasaki, Masaki.
Afiliação
  • Takayama Y; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Ikegaya N; Department of Neurosurgery, Yokohama City University Graduate School of Medicine, Yokohama 236-0004, Kanagawa, Japan.
  • Iijima K; Department of Neurosurgery, Yokohama City University Graduate School of Medicine, Yokohama 236-0004, Kanagawa, Japan.
  • Kimura Y; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Yokosako S; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Muraoka N; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Kosugi K; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Kaneko Y; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Yamamoto T; Department of Neurosurgery, National Center Hospital, National Center of Neurology and Psychiatry, Kodaira, Tokyo 187-8551, Japan.
  • Iwasaki M; Department of Neurosurgery, Yokohama City University Graduate School of Medicine, Yokohama 236-0004, Kanagawa, Japan.
Brain Sci ; 11(3)2021 Feb 28.
Article em En | MEDLINE | ID: mdl-33671088
ABSTRACT
Implantation of subdural electrodes on the brain surface is still widely performed as one of the "gold standard methods" for the presurgical evaluation of epilepsy. Stereotactic insertion of depth electrodes to the brain can be added to detect brain activities in deep-seated lesions to which surface electrodes are insensitive. This study tried to clarify the efficacy and limitations of combined implantation of subdural and depth electrodes in intractable epilepsy patients. Fifty-three patients with drug-resistant epilepsy underwent combined implantation of subdural and depth electrodes for long-term intracranial electroencephalography (iEEG) before epilepsy surgery. The detectability of early ictal iEEG change (EIIC) were compared between the subdural and depth electrodes. We also examined clinical factors including resection of MRI lesion and EIIC with seizure freedom. Detectability of EIIC showed no significant difference between subdural and depth electrodes. However, the additional depth electrode was useful for detecting EIIC from apparently deep locations, such as the insula and mesial temporal structures, but not in detecting EIIC in patients with ulegyria (glial scar). Total removal of MRI lesion was associated with seizure freedom. Depth electrodes should be carefully used after consideration of the suspected etiology to avoid injudicious usage.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Brain Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Brain Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão