Your browser doesn't support javascript.
loading
Accuracy, Labor-Time and Patient-Reported Outcomes with Partially versus Fully Digital Workflow for Flapless Guided Dental Implants Insertion-A Randomized Clinical Trial with One-Year Follow-Up.
Cristache, Corina Marilena; Burlibasa, Mihai; Tudor, Ioana; Totu, Eugenia Eftimie; Di Francesco, Fabrizio; Moraru, Liliana.
Afiliação
  • Cristache CM; Department of Dental Techniques, Faculty of Midwifery and Medical Assisting (FMAM), "Carol Davila" University of Medicine and Pharmacy, 8 Eroilor Sanitari Blvd, 050474 Bucharest, Romania.
  • Burlibasa M; Department of Dental Techniques, Faculty of Midwifery and Medical Assisting (FMAM), "Carol Davila" University of Medicine and Pharmacy, 8 Eroilor Sanitari Blvd, 050474 Bucharest, Romania.
  • Tudor I; Department of Dental Techniques, Faculty of Midwifery and Medical Assisting (FMAM), "Carol Davila" University of Medicine and Pharmacy, 8 Eroilor Sanitari Blvd, 050474 Bucharest, Romania.
  • Totu EE; Smart Biomaterials and Applications Master Program, Faculty of Medical Engineering, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania.
  • Di Francesco F; Department of Analytical Chemistry, Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, 1-7 Polizu St., Sector 1, 011061 Bucharest, Romania.
  • Moraru L; Multidisciplinary Department of Medical, Surgical and Oral Sciences, Campania University Luigi Vanvitelli (ex Second University of Naples), 6 Via Luigi De Crecchio, 80138 Napoli, Italy.
J Clin Med ; 10(5)2021 Mar 06.
Article em En | MEDLINE | ID: mdl-33800946
ABSTRACT
(1)

Background:

Prosthetically-driven implant positioning is a prerequisite for long-term successful treatment. Transferring the planned implant position information to the clinical setting could be done using either static or dynamic guided techniques. The 3D model of the bone and surrounding structures is obtained via cone beam computed tomography (CBCT) and the patient's oral condition can be acquired conventionally and then digitalized using a desktop scanner, partially digital workflow (PDW) or digitally with the aid of an intraoral scanner (FDW). The aim of the present randomized clinical trial (RCT) was to compare the accuracy of flapless dental implants insertion in partially edentulous patients with a static surgical template obtained through PDW and FDW. Patient outcome and time spent from data collection to template manufacturing were also compared. (2)

Methods:

66 partially edentulous sites (at 49 patients) were randomly assigned to a PDW or FDW for guided implant insertion. Planned and placed implants position were compared by assessing four deviation parameters 3D error at the entry point, 3D error at the apex, angular deviation, and vertical deviation at entry point. (3)

Results:

A total of 111 implants were inserted. No implant loss during osseointegration or mechanical and technical complications occurred during the first-year post-implants loading. The mean error at the entry point was 0.44 mm (FDW) and 0.85 (PDW), p ≤ 0.00; at implant apex, 1.03 (FDW) and 1.48 (PDW), p ≤ 0.00; the mean angular deviation, 2.12° (FDW) and 2.48° (PDW), p = 0.03 and the mean depth deviation, 0.45 mm (FDW) and 0.68 mm (PDW), p ≤ 0.00; (4)

Conclusions:

Despite the statistically significant differences between the groups, and in the limits of the present study, full digital workflow as well as partially digital workflow are predictable methods for accurate prosthetically driven guided implants insertion.