Your browser doesn't support javascript.
loading
Taking the Next Steps in Endoscopic Visual Assessment of Barrett's Esophagus: A Pilot Study.
Chis, Roxana; Hew, Simon; Hopman, Wilma; Hookey, Lawrence; Bechara, Robert.
Afiliação
  • Chis R; Division of Internal Medicine, Kingston Health Sciences Centre, Queen's University, Kingston, Ontario, Canada.
  • Hew S; Division of Gastroenterology, Kingston Health Sciences Centre, Queen's University, Kingston General Hospital, Kingston, Ontario, Canada.
  • Hopman W; Research Institute, Kingston Health Sciences Centre, Queen's University, Kingston, Ontario, Canada.
  • Hookey L; Division of Gastroenterology, Kingston Health Sciences Centre, Queen's University, Kingston General Hospital, Kingston, Ontario, Canada.
  • Bechara R; Division of Gastroenterology, Kingston Health Sciences Centre, Queen's University, Kingston General Hospital, Kingston, Ontario, Canada.
Clin Exp Gastroenterol ; 14: 113-122, 2021.
Article em En | MEDLINE | ID: mdl-33911891
PURPOSE: Patients with Barrett's esophagus (BE) undergo surveillance endoscopies to assess for pre-cancerous changes. We developed a simple endoscopic classification method for predicting non-dysplastic BE (NDBE), low-grade dysplasia (LGD)/indefinite for dysplasia (ID) and high-grade dysplasia (HGD)/early esophageal adenocarcinoma (EAC). PATIENTS AND METHODS: Twenty-two patients with BE underwent endoscopy using the PENTAX Medical MagniView gastroscope and OPTIVISTA processor. Sixty-six video-still images were analyzed to characterize the microsurface, microvasculature and the presence of a demarcation line. Class A was characterized by regular microvascular and microsurface patterns and absence of a demarcation line, class B by changes in the microvascular and/or microsurface patterns compared to the background mucosa with presence of a demarcation line, and class C by irregular microvascular and/or irregular microsurface patterns with presence of a demarcation line. RESULTS: Of the class A images, 97.9% were NDBE. For class B, 69.2% were LGD/ID and 30.8% NDBE. One hundred percent of the class C samples were HGD/EAC. The sensitivity of our classification system was 93.8%, specificity 92%, positive predictive value 78.9%, negative predictive value 97.9% and an accuracy 92.4%. CONCLUSION: In this study, we developed a simple classification system for the prediction of NDBE, LGD/ID and HGD/EAC. Its real-time clinical applicability will be validated prospectively.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Exp Gastroenterol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá País de publicação: Nova Zelândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Exp Gastroenterol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá País de publicação: Nova Zelândia