Your browser doesn't support javascript.
loading
Validation of Plantar Pressure and Reaction Force Measured by Moticon Pressure Sensor Insoles on a Concept2 Rowing Ergometer.
Barratt, Georgina Kate; Bellenger, Clint; Robertson, Eileen Yule; Lane, Jason; Crowther, Robert George.
Afiliação
  • Barratt GK; UniSA: Allied Health and Human Performance, University of South Australia, 5001 Adelaide, Australia.
  • Bellenger C; Alliance for Research in Exercise, Nutrition & Activity (ARENA), University of South Australia, 5001 Adelaide, Australia.
  • Robertson EY; UniSA: Allied Health and Human Performance, University of South Australia, 5001 Adelaide, Australia.
  • Lane J; Alliance for Research in Exercise, Nutrition & Activity (ARENA), University of South Australia, 5001 Adelaide, Australia.
  • Crowther RG; South Australian Sports Institute, 5025 Adelaide, Australia.
Sensors (Basel) ; 21(7)2021 Apr 01.
Article em En | MEDLINE | ID: mdl-33915797
ABSTRACT
The purpose of this study was to determine the reliability and validity of plantar pressure and reaction force measured using the Moticon and Pedar-x sensor insoles while rowing on a Concept2 ergometer. Nineteen participants performed four 500 m trials of ergometer rowing at 22-24 strokes/min; two trials wearing Moticon insoles and two wearing Pedar-x insoles in a randomised order. Moticon and Pedar-x insoles both showed moderate to strong test-retest reliability (ICC = 0.57-0.92) for mean and peak plantar pressure and reaction force. Paired t-test demonstrated a significant difference (p < 0.001) between Moticon and Pedar-x insoles, effect size showed a large bias (ES > 1.13), and Pearson's correlation (r < 0.37) showed poor agreement for all plantar pressure and reaction force variables. Compared to Pedar-x, the Moticon insoles demonstrated poor validity, however, the Moticon insoles had strong reliability. Due to poor validity, caution should be used when considering Moticon insoles to assess changes in pressure and force reliably over time, across multiple trials or sessions. Moticon's wireless and user-friendly application would be beneficial for assessing and monitoring biomechanical parameters in rowing if validity between measures of interest and Moticon's results can be established.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sapatos / Esportes Aquáticos Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sapatos / Esportes Aquáticos Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Austrália