Your browser doesn't support javascript.
loading
Liposome-assisted enzyme catalysis: toward signal amplification for sensitive split-type electrochemiluminescence immunoassay.
Fu, Yi-Zhuo; Liu, Xiang-Mei; Ma, Shu-Hui; Cao, Jun-Tao; Liu, Yan-Ming.
Afiliação
  • Fu YZ; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com jtcao11@163.com.
  • Liu XM; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com jtcao11@163.com.
  • Ma SH; Xinyang Central Hospital, Xinyang 464000, China.
  • Cao JT; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com jtcao11@163.com.
  • Liu YM; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang 464000, China. liuym9518@sina.com jtcao11@163.com.
Analyst ; 146(12): 3918-3923, 2021 Jun 14.
Article em En | MEDLINE | ID: mdl-33973589
ABSTRACT
Developing an efficient signal amplification strategy is very important to improve the sensitivity of bioanalysis. In this paper, a liposome-assisted enzyme catalysis signal amplification strategy was developed for electrochemiluminescence (ECL) immunoassay of prostate specific antigen (PSA) in a split-type mode. The sandwich immunoreaction occurred in a 96-well plate, and glucose oxidase (GOx) encapsulated and antibody-modified liposomes were used as labels. The ECL detection was carried out using a rGO-Au NP modified glassy carbon electrode (GCE). The large amount of generated H2O2, i.e. the coreactant of the luminol system, and the excellent catalytic behavior of rGO-Au NPs greatly boosted the ECL signal, resulting in the signal amplification. The developed ECL immunosensor for detecting PSA achieved a wider linear range from 1.0 × 10-13 to 1.0 × 10-8 g mL-1 and a detection limit of 1.7 × 10-14 g mL-1. The application of the proposed strategy was demonstrated by analyzing PSA in human serum samples with recoveries from 89.0% to 113.0%, and relative standard deviations (RSDs) were less than 6.6%. This work provides a new horizon to expand the application of liposomes for ECL bioanalysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans / Male Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article