Your browser doesn't support javascript.
loading
Efficacy and safety of the Clearum dialyzer.
Maduell, Francisco; Broseta, José Jesús; Rodríguez-Espinosa, Diana; Hermida-Lama, Evelyn; Cuadrado-Payán, Elena; Rodas, Lida María; Gómez, Miquel; Arias-Guillén, Marta; Fontseré, Néstor; Vera, Manel; Rico, Nayra.
Afiliação
  • Maduell F; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Broseta JJ; Department of Medicine, University of Barcelona, Barcelona, Spain.
  • Rodríguez-Espinosa D; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Hermida-Lama E; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Cuadrado-Payán E; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Rodas LM; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Gómez M; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Arias-Guillén M; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Fontseré N; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Vera M; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
  • Rico N; Department of Nephrology, Hospital Clínic Barcelona, Barcelona, Spain.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Article em En | MEDLINE | ID: mdl-33978975
The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diálise Renal / Hemodiafiltração / Falência Renal Crônica Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diálise Renal / Hemodiafiltração / Falência Renal Crônica Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Artif Organs Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha País de publicação: Estados Unidos