Your browser doesn't support javascript.
loading
Identifying bronchoconstriction from the ratio of diaphragm EMG to tidal volume.
He, Bai-Ting; Luo, Ying-Mei; Wang, Li-Shuang; Chen, Yong-Yi; Jolley, Caroline; Steier, Joerg; Moxham, John; Polkey, Michael L; Luo, Yuanming.
Afiliação
  • He BT; State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
  • Luo YM; State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
  • Wang LS; State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
  • Chen YY; State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China.
  • Jolley C; Faculty of Life Sciences and Medicine, King's College London School of Medicine, London, UK.
  • Steier J; Faculty of Life Sciences and Medicine, King's College London School of Medicine, London, UK.
  • Moxham J; Faculty of Life Sciences and Medicine, King's College London School of Medicine, London, UK.
  • Polkey ML; Respiratory Muscle Laboratory, the Royal Brompton Hospital, London, UK.
  • Luo Y; State Key Laboratory of Respiratory Disease, Guangzhou Medical University, Guangzhou, China; Faculty of Life Sciences and Medicine, King's College London School of Medicine, London, UK; Adelaide Institute for Sleep Health, College of Medicine and Public Health, Flinders University, Australia. Electr
Respir Physiol Neurobiol ; 291: 103692, 2021 09.
Article em En | MEDLINE | ID: mdl-34020067
ABSTRACT

BACKGROUND:

A fall of ≥ 20 % in forced expiratory volume in the first second (FEV1) with a cumulative dose of histamine ≤ 7.8 µmol is considered to indicate bronchial hyperactivity, but no method exists for patients who cannot perform spirometry properly. Here we hypothesized that increases in respiratory central output measured by chest wall electromyography of the diaphragm (EMGdi-c) expressed as a function of tidal volume (EMGdi-c/VT) would have discriminative power to detect a 'positive' challenge test.

METHODS:

In a physiological study EMGdi was recorded from esophageal electrode (EMGdi-e) in 16 asthma patients and 16 healthy subjects during a histamine challenge test. In a second study, EMGdi from chest wall surface electrodes (EMGdi-c) was measured during a histamine challenge in 44 asthma patients and 51 healthy subjects. VT was recorded from a digital flowmeter during both studies.

RESULTS:

With histamine challenge test the change in EMGdi-e/VT in patients with asthma was significantly higher than that in healthy subjects (104.2 % ± 48.6 % vs 0.03 % ± 17.1 %, p < 0.001). Similarly there was a significant difference in the change of EMGdi-c/VT between patients with asthma and healthy subjects (90.5 % ± 75.5 % vs 2.4 % ± 21.7 %, p < 0.001). At the optimal cut-off point (29 % increase in EMGdi-c/VT), the area under the ROC curve (AUC) for detection of a positive test was 0.91 (p < 0.001) with sensitivity 86 % and specificity 92 %.

CONCLUSIONS:

We conclude that EMGdi-c/VT may be used as an alternative for the assessment of bronchial hypersensitivity and airway reversibility to differentiate patients with asthma from healthy subjects.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Broncodilatadores / Diafragma / Histamina / Volume de Ventilação Pulmonar / Broncoconstrição / Hiper-Reatividade Brônquica Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Physiol Neurobiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Broncodilatadores / Diafragma / Histamina / Volume de Ventilação Pulmonar / Broncoconstrição / Hiper-Reatividade Brônquica Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Respir Physiol Neurobiol Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China