Surface metrology of bone surface attachments of knee ligaments.
Hoehmann, Christopher L; Beatty, Brian Lee.
Afiliação
  • Hoehmann CL; Department of Orthopaedic Surgery, Nassau University Medical Center, East Meadow, New York, USA.
  • Beatty BL; New York Institute of Technology College of Osteopathic Medicine, Old Westbury, New York, USA.
Anat Rec (Hoboken) ; 305(1): 52-65, 2022 01.
Article em En | MEDLINE | ID: mdl-34021967
ABSTRACT

OBJECTIVES:

Textural differences between entheses reflect biomechanical activities of the musculoskeletal system. Methods used to measure these surfaces have limitations. Here, the surface metrology of roughness of articular and entheseal surfaces of the knee are investigated with an optical profiler.

METHODS:

Osteological specimens of six femora and seven tibiae were prepared from cadavers. Measurements were obtained to surrogate body mass. Specimens were molded with polyvinylsiloxane and casts prepared with resin, which were scanned using a white light optical profiler. Scans were processed by a computer program. Each scan produced 32 variables, categorized into 6 groups for each location.

RESULTS:

The distribution of data was mostly normal. Analysis of variance (ANOVA) identified Ssk significant (p-value .002); post hoc Tukey testing indicated significance between femoral PCL and tibial ACL entheses groups (p-value .007), and between tibial ACL and tibial entheses groups (p-value .002) suggesting the ability to differentiate anterior and posterior cruciate ligament entheses. Sku was found significant with a t test between articular and entheseal surfaces. Correlation coefficients were significant between surface metrology parameters and measurements related to body mass.

CONCLUSIONS:

This study distinguished differences between entheses of the anterior and posterior cruciate ligaments, with the Ssk parameter most useful. Differences in articular and entheseal surfaces were found with the Sku parameter most useful. Correlations indicated a relationship between body mass and surface metrology parameters. Finally, these findings suggest this method can be used for further investigation of spondyloarthropathies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Ligamento Cruzado Posterior Tipo de estudo: Prognostic_studies Idioma: En Revista: Anat Rec (Hoboken) Assunto da revista: ANATOMIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ligamento Cruzado Anterior / Ligamento Cruzado Posterior Tipo de estudo: Prognostic_studies Idioma: En Revista: Anat Rec (Hoboken) Assunto da revista: ANATOMIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos