Your browser doesn't support javascript.
loading
Effect of Modeling Resins on Microhardness of Resin Composites.
Bayraktar, Ezgi T; Atali, Pinar Y; Korkut, Bora; Kesimli, Ezgi G; Tarcin, Bilge; Turkmen, Cafer.
Afiliação
  • Bayraktar ET; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
  • Atali PY; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
  • Korkut B; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
  • Kesimli EG; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
  • Tarcin B; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
  • Turkmen C; Department of Restorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey.
Eur J Dent ; 15(3): 481-487, 2021 Jul.
Article em En | MEDLINE | ID: mdl-34041724
ABSTRACT

OBJECTIVES:

This study was aimed to determine the effects of modeling resins on the surface microhardness of composites. MATERIALS AND

METHODS:

Six resin-based composites (Charisma Smart, Estellite Asteria, CeramX-One SphereTEC, Admira Fusion, Filtek Ultimate, and Clearfil Majesty Es-2) and three wetting agents (Modeling Liquid, Composite Primer, and Modeling Resin) were investigated. In all, 240 specimens were prepared, and wetting agents were applied prior to light curing in the experimental groups. After 24 hours, specimens were polished and Vickers microhardness (VHN) values were measured. STATISTICAL

ANALYSIS:

Shapiro-Wilk and two-way analysis of variance (ANOVA) were used for analyses (p < 0.05).

RESULTS:

Both modeling resin and composites were determined to be effective factors (p < 0.001). The control group showed the highest VHN (70.37 ± 7.94), followed by Modeling Liquid (64.68 ± 12.07), Composite Primer (59.84 ± 6.33), and Modeling Resin (58 ± 3.52b; p < 0.001). Filtek Ultimate showed the highest VHN (76.62 ± 9.78c), whereas Charisma Smart (58.87 ± 7.95), and Clearfil Majesty (67.27 ± 2.58) showed the lowest (p < 0.001). Clearfil Majesty-Modeling Liquid (46.62 ± 5.33) and Charisma Smart-Composite Primer (50.81 ± 0.39) combinations showed the lowest VHN, whereas Filtek Ultimate-control (87.15 ± 2.12) and Filtek Ultimate-Modeling Liquid (84.24 ± 3.11) showed the highest (p < 0.001).

CONCLUSION:

All tested modeling resins decreased VHN value, and the amount of reduction varied among composites and wetting agents. It might be safer not to use wetting agents unless they are necessary.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Eur J Dent Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Eur J Dent Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia