Your browser doesn't support javascript.
loading
Impact of 24/7 loading of blood culture bottles in a new automated incubator on the diagnosis of bloodstream infections.
Péan de Ponfilly, Gauthier; Benmansour, H; Manda, V; Lecorche, E; Mougari, F; Munier, A L; Temim, S; Amarsy, R; Jacquier, H; Cambau, E.
Afiliação
  • Péan de Ponfilly G; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France. gpeandeponfilly@ghpsj.fr.
  • Benmansour H; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France.
  • Manda V; Department of Infectious Diseases, Saint Louis - Lariboisière - Fernand Widal University Hospital, APHP, Paris, France.
  • Lecorche E; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France.
  • Mougari F; Université de Paris, INSERM, UMR1137, IAME, Paris, France.
  • Munier AL; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France.
  • Temim S; Department of Infectious Diseases, Saint Louis - Lariboisière - Fernand Widal University Hospital, APHP, Paris, France.
  • Amarsy R; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France.
  • Jacquier H; Equipe opérationnelle d'Hygiène hospitalière, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, Paris, France.
  • Cambau E; Laboratoire de Microbiologie, BioGem, APHP Nord, Hôpitaux Lariboisière - Fernand Widal, 75014, Paris, France.
Eur J Clin Microbiol Infect Dis ; 40(12): 2639-2643, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34059934
ABSTRACT
Blood culturing (BC) remains the gold standard for bloodstream diagnosis but its workflow is slow. We aimed reducing this time by implementing a new automated incubator with a 24/7 BC workflow. With this new strategy, time to incubation was shorter (1.52 h vs 6.82 h), positivity rates were higher (10.6% vs 8.9%, p<0.05), and the number of BSI diagnostics increased (16.1% vs 13.8% patients and 2.3 vs 1.9 density episode per 1000 hospital days). Our results show that implementing automatic loading of BC bottles with a 24/7 strategy not only shortened time to diagnosis but significantly increased the BSI diagnosis rate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Bactérias / Bacteriemia / Hemocultura Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Automação / Bactérias / Bacteriemia / Hemocultura Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Assunto da revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França
...