Your browser doesn't support javascript.
loading
Identification and quantification of glucose degradation products in heat-sterilized glucose solutions for parenteral use by thin-layer chromatography.
Leitzen, Sarah; Vogel, Matthias; Engels, Anette; Zapf, Thomas; Brandl, Martin.
Afiliação
  • Leitzen S; Department of Physics, Chemistry and Pharmacy, University of Southern Denmark, Odense, Denmark.
  • Vogel M; Federal Institute for Drugs and Medical Devices, Bonn, Germany.
  • Engels A; Federal Institute for Drugs and Medical Devices, Bonn, Germany.
  • Zapf T; Federal Institute for Drugs and Medical Devices, Bonn, Germany.
  • Brandl M; Federal Institute for Drugs and Medical Devices, Bonn, Germany.
PLoS One ; 16(7): e0253811, 2021.
Article em En | MEDLINE | ID: mdl-34214128
ABSTRACT
During heat sterilization of glucose solutions, a variety of glucose degradation products (GDPs) may be formed. GDPs can cause cytotoxic effects after parenteral administration of these solutions. The aim of the current study therefore was to develop a simple and quick high-performance thin-layer chromatography (HPTLC) method by which the major GDPs can be identified and (summarily) quantified in glucose solutions for parenteral administration. All GDPs were derivatized with o-phenylenediamine (OPD). The resulting GDP derivatives (quinoxalines) were applied to an HPTLC plate. After 20 minutes of chamber saturation with the solvent, the HPTLC plate was developed in a mixture of 1,4-dioxane-toluene-glacial acetic acid (49492, v/v/v), treated with thymol-sulfuric acid spray reagent, and heated at 130°C for 10 minutes. Finally, the GDPs were quantified by using a TLC scanner. For validation, the identities of the quinoxaline derivatives were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Glyoxal (GO)/methylglyoxal (MGO) and 3-deoxyglucosone (3-DG)/3-deoxygalactosone (3-DGal) could be identified and quantified in pairs, glucosone (2-KDG), 5-hydroxymethylfurfural (5-HMF), and 3,4-dideoxyglucosone-3-ene (3,4-DGE) each individually. For 2-KDG, the linearity of the method was demonstrated in the range of 1-50 µg/mL, for 5-HMF and 3,4-DGE 1-75 µg/mL, for GO/MGO 2-150 µg/mL, and for 3-DG/3-DGal 10-150 µg/mL. All GDPs achieved a limit of detection (LOD) of 2 µg/mL or less and a limit of quantification (LOQ) of 10 µg/mL or less. R2 was 0.982 for 3.4-DGE, 0.997 for 5-HMF, and 0.999 for 2-KDG, 3-DG/3-DGal, and GO/MGO. The intraday precision was between 0.4 and 14.2% and the accuracy, reported as % recovery, between 86.4 and 112.7%. The proposed HPTLC method appears to be an inexpensive, fast, and sufficiently sensitive approach for routine quantitative analysis of GDPs in heat-sterilized glucose solutions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Estabilidade de Medicamentos / Glucose / Temperatura Alta Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Estabilidade de Medicamentos / Glucose / Temperatura Alta Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Dinamarca País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA