Your browser doesn't support javascript.
loading
Modifying thin-film composite forward osmosis membranes using various SiO2 nanoparticles for aquaculture wastewater recovery.
Nguyen, Truc-Quynh; Tung, Kuo-Lun; Lin, Yi-Li; Dong, Cheng-Di; Chen, Chiu-Wen; Wu, Chung-Hsin.
Afiliação
  • Nguyen TQ; Department of Safety Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 824, Taiwan; Department of Forestry and Environmental Engineering, South-Eastern Finland University of Applied Sciences, Mikkeli, 50100, Finland.
  • Tung KL; Department of Chemical Engineering, National Taiwan University, Taipei, 106, Taiwan.
  • Lin YL; Department of Safety Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 824, Taiwan. Electronic address: yililin@nkust.edu.tw.
  • Dong CD; Department of Marine Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 81157, Taiwan.
  • Chen CW; Department of Marine Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 81157, Taiwan.
  • Wu CH; Department of Chemical and Materials Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 80,778, Taiwan.
Chemosphere ; 281: 130796, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34289641
ABSTRACT
This paper describes the fabrication, modification, and evaluation of the performance of thin-film composite (TFC) forward osmosis (FO) membranes for lab-scale aquaculture wastewater recovery using various fumed silica (SiO2) nanoparticles. The active polyamide (PA) layers of these membranes were novelly modified using different types of pretreated SiO2 nanoparticles [virgin SiO2, dried SiO2, and 3-aminopropyltriethoxysilane (APTES)-modified SiO2] and concentrations (0.05, 0,1, 0,2, and 0.4 wt%) to improve the membrane hydrophilicity with minimum particle agglomeration. Results show that the APTES-SiO2 modified membrane had the highest water flux and selectivity, followed by the dried-SiO2 modified membrane. The APTES coupling agent notably reduced the SiO2 aggregation on the membrane surface and improved membrane hydrophilicity. Consequently, high permeate flux and an acceptable reverse solute flux were observed. The optimal SiO2 concentration for PA modification was 0.1 wt% for all the nanoparticle types. The virgin and APTES-SiO2 modified membranes were used for aquaculture wastewater recovery. The water recovery rate reached 47% in 84 h when using the APTES-SiO2 modified membrane, while it reached only 26% in 108 h when using the virgin membrane. With a suitable design of the filtration apparatus and choice of draw solution (DS), the prepared novel TFC-FO membrane containing APTES-modified SiO2 can be used for recycling aquaculture wastewater into the DS, which can then be reused for other purposes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Nanopartículas Idioma: En Revista: Chemosphere Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Nanopartículas Idioma: En Revista: Chemosphere Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Finlândia