High-performance liquid chromatographic determination of glipizide in human plasma and urine.
Emilsson, H.
Afiliação
  • Emilsson H; Department of Pharmacy, Karolinska Institute, Huddinge Hospital, Sweden.
J Chromatogr ; 421(2): 319-26, 1987 Oct 30.
Article em En | MEDLINE | ID: mdl-3429586
ABSTRACT
A sensitive and selective high-performance liquid chromatographic method for determination of intact glipizide in human plasma or urine has been developed. The plasma and urine samples were acid-buffered, before tolbutamide was added as internal standard. The samples were extracted with benzene, and the organic layer was evaporated to dryness. The residue was dissolved in equilibrated mobile phase (acetonitrile-0.01 M phosphate buffer pH 3.5, 3565), and an aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column. Quantitation was achieved by monitoring the ultraviolet absorbance at 275 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents were observed. The utility of the assay was demonstrated by determining glipizide in samples from a diabetic subject receiving a therapeutic dose of 5 mg of the drug.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Sulfonilureia / Glipizida Limite: Humans Idioma: En Revista: J Chromatogr Ano de publicação: 1987 Tipo de documento: Article País de afiliação: Suécia
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Sulfonilureia / Glipizida Limite: Humans Idioma: En Revista: J Chromatogr Ano de publicação: 1987 Tipo de documento: Article País de afiliação: Suécia