Evaluation of 20 clinical chemistry and 12 immunoassay analytes in terms of total analytical error and measurement uncertainty.
Balik, Ahmet Rifat; Gücel, Funda.
Afiliação
  • Balik AR; Medical Biochemistry Laboratory, Ankara Gülhane Training and Research Hospital, Ankara, Turkey.
  • Gücel F; Medical Biochemistry Laboratory, Ankara Etlik Zübeyde Hanim Gynecology Training and Research Hospital, Ankara, Turkey.
Scand J Clin Lab Invest ; 81(7): 517-522, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34314276
In analytical quality management, target setting models that are selected by the purpose together with the error models that are applied correctly have critical importance. In our study, we aimed to compare the analytical performance characteristics of routine clinical chemistry and immunoassay tests with different target-setting models proposed by various organizations. Our study was performed with internal and external quality control data obtained using Beckman Coulter AU680 for clinical chemistry analytes and Roche Cobas 8000 autoanalyzer for immunoassay analytes. The total analytical error (TAE) was calculated by the formula TAH%=1.65×(CV%)+Bias%. Measurement uncertainty (MU) has been calculated adhering to the Nordtest guideline. Results were compared with BVEFLM, CLIA, RCPA, PRDEQA%, pUEQAS%, and permissible MU (pU%) data to investigate analytical performance qualities. When we compare the results of TAE and MU, MU was found to be higher than TAE for all analytes. ALT, AST, glucose, K, and triglycerides met all target values, showing the best performance. Taken together, our results show that CLIA for total analytical error and PRDEQA% and pUEQAS% for measurement uncertainty can match better than BVEFLM, RCPA and pU%. These test results should be evaluated with measurement uncertainty to avoid misdiagnosis. Appropriate specification limits should be defined for the examination of test methods that meet the objectives for fitness for clinical purposes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Química Clínica / Incerteza Tipo de estudo: Evaluation_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Scand J Clin Lab Invest Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Química Clínica / Incerteza Tipo de estudo: Evaluation_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Scand J Clin Lab Invest Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia País de publicação: Reino Unido