Your browser doesn't support javascript.
loading
Using Ultrasound Color Doppler Twinkling to Identify Biopsy Markers in the Breast and Axilla.
Lee, Christine U; Hesley, Gina K; Uthamaraj, Susheil; Larson, Nicholas B; Greenleaf, James F; Urban, Matthew W.
Afiliação
  • Lee CU; Department of Radiology, Breast Imaging and Intervention Division, Mayo Clinic, Rochester, MN, USA. Electronic address: lee.christine@mayo.edu.
  • Hesley GK; Department of Radiology, Breast Imaging and Intervention Division, Mayo Clinic, Rochester, MN, USA.
  • Uthamaraj S; Division of Engineering, Mayo Clinic, Rochester, MN, USA.
  • Larson NB; Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN, USA.
  • Greenleaf JF; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Urban MW; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Department of Radiology, Division of Radiology Research, Mayo Clinic, Rochester, MN, USA.
Ultrasound Med Biol ; 47(11): 3122-3134, 2021 11.
Article em En | MEDLINE | ID: mdl-34412903
ABSTRACT
In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Ultrassonografia Doppler em Cores Tipo de estudo: Diagnostic_studies / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Ultrassonografia Doppler em Cores Tipo de estudo: Diagnostic_studies / Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2021 Tipo de documento: Article