Your browser doesn't support javascript.
loading
To screen or not to screen? The development of a prediction model for aorto-iliac stenosis in kidney transplant candidates.
Rijkse, Elsaline; Qi, Hongchao; Babakry, Shabnam; Bijdevaate, Diederik C; Kimenai, Hendrikus J A N; Roodnat, Joke I; IJzermans, Jan N M; Minnee, Robert C.
Afiliação
  • Rijkse E; Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Qi H; Department of Biostatistics, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Babakry S; Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Bijdevaate DC; Department of Radiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Kimenai HJAN; Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Roodnat JI; Division of Nephrology, Department of Internal Medicine, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • IJzermans JNM; Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
  • Minnee RC; Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
Transpl Int ; 34(11): 2371-2381, 2021 Nov.
Article em En | MEDLINE | ID: mdl-34416037
ABSTRACT
Screening for aorto-iliac stenosis is important in kidney transplant candidates as its presence affects pre-transplantation decisions regarding side of implantation and the need for an additional vascular procedure. Reliable imaging techniques to identify this condition require contrast fluid, which can be harmful in these patients. To guide patient selection for these imaging techniques, we aimed to develop a prediction model for the presence of aorto-iliac stenosis. Patients with contrast-enhanced imaging available in the pre-transplant screening between January 1st, 2000 and December 31st, 2018 were included. A prediction model was developed using multivariable logistic regression analysis and internally validated using bootstrap resampling. Model performance was assessed with the concordance index and calibration slope. Three hundred and seventy-three patients were included, 90 patients (24.1%) had imaging-proven aorto-iliac stenosis. Our final model included age, smoking, peripheral arterial disease, coronary artery disease, a previous transplant, intermittent claudication and the presence of a femoral artery murmur. The model yielded excellent discrimination (optimism-corrected concordance index 0.83) and calibration (optimism-corrected calibration slope 0.91). In conclusion, this prediction model can guide the development of standardized protocols to decide which patients should receive vascular screening to identify aorto-iliac stenosis. External validation is needed before this model can be implemented in patient care.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplante de Rim Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Transpl Int Assunto da revista: TRANSPLANTE Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplante de Rim Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Transpl Int Assunto da revista: TRANSPLANTE Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda