Your browser doesn't support javascript.
loading
Long-Term Corrosion Testing of Zy-4 in a LiOH Solution under High Pressure and Temperature Conditions.
Diniasi, Diana; Golgovici, Florentina; Marin, Alexandru Horia; Negrea, Aurelian Denis; Fulger, Manuela; Demetrescu, Ioana.
Afiliação
  • Diniasi D; Institute for Nuclear Research Pitesti, POB 78, Campului Street, No. 1, 115400 Mioveni, Romania.
  • Golgovici F; Department of General Chemistry, Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, Splaiul Independentei Street, No. 313, 060042 Bucharest, Romania.
  • Marin AH; Institute for Nuclear Research Pitesti, POB 78, Campului Street, No. 1, 115400 Mioveni, Romania.
  • Negrea AD; Regional Center of Research & Development for Materials, Processes and Innovative Products Dedicated to the Automotive Industry (CRC&D-AUTO), University of Pitesti, Doaga Street, No. 11, 110040 Pitesti, Romania.
  • Fulger M; Institute for Nuclear Research Pitesti, POB 78, Campului Street, No. 1, 115400 Mioveni, Romania.
  • Demetrescu I; Department of General Chemistry, Faculty of Applied Chemistry and Materials Science, University Politehnica of Bucharest, Splaiul Independentei Street, No. 313, 060042 Bucharest, Romania.
Materials (Basel) ; 14(16)2021 Aug 15.
Article em En | MEDLINE | ID: mdl-34443109
ABSTRACT
The fuel cladding is one of the most important structural components for maintaining the integrity of a fuel channel and for safely exploitation of a nuclear power plant. The corrosion behavior of a fuel cladding material, Zy-4, under high pressure and temperatures conditions, was analyzed in a static isothermal autoclave under simulated primary water conditions-a LiOH solution at 310 °C and 10 MPa for up to 3024 h. After this, the oxides grown on the Zy-4 sample surface were characterized using electrochemical measurements, gravimetric analysis, metallographic analysis, SEM and XPS. The maximum oxide thicknesses evaluated by gravimetric and SEM measurements were in good agreement; both values were around 1.2 µm. The optical light microscopy (OLM) investigations identified the presence of small hydrides uniformly distributed horizontally across the alloy. EIS impedance spectra showed an increase in the oxide impedance for the samples oxidized for a long time. EIS plots has the best fit with an equivalent circuit which illustrated an oxide model that has two oxide layers an inner oxide layer and outer layer. The EIS results showed that the inner layer was a barrier layer, and the outer layer was a porous layer. Potentiodynamic polarization results demonstrated superior corrosion resistance of the samples tested for longer periods of time. By XPS measurements we identified all five oxidation states of zirconium Zr0 located at 178.5 eV; Zr4+ at 182.8 eV; and the three suboxides, Zr+, Zr2+ and Zr3+ at 179.7, 180.8 and 181.8 eV, respectively. The determination of Vickers microhardness completed the investigation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Romênia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Romênia