Your browser doesn't support javascript.
loading
Decision Threshold for Kryptor sFlt-1/PlGF Ratio in Women With Suspected Preeclampsia: Retrospective Study in a Routine Clinical Setting.
Andersen, Lise Lotte Torvin; Helt, Annemarie; Sperling, Lene; Overgaard, Martin.
Afiliação
  • Andersen LLT; Department of Obstetrics and Gynecology Odense University Hospital Odense Denmark.
  • Helt A; Department of Obstetrics and Gynecology Odense University Hospital Odense Denmark.
  • Sperling L; Department of Obstetrics and Gynecology Odense University Hospital Odense Denmark.
  • Overgaard M; Department of Clinical Research University of Southern Denmark Odense Denmark.
J Am Heart Assoc ; 10(17): e021376, 2021 09 07.
Article em En | MEDLINE | ID: mdl-34459248
ABSTRACT
Background The objective was to evaluate predictive performance and optimal decision threshold of the Kryptor soluble fms-like tyrosine kinase-1 (sFlt-1)/placental growth factor (PlGF) ratio when implemented for routine management of women presenting with symptoms of preeclampsia. Methods and Results Observational retrospective study of a cohort of 501 women with suspected preeclampsia after 20 weeks of gestation. Women referred to maternity ward for observation of preeclampsia had an sFlt-1/PlGF ratio test included in routine diagnostic workup. Maternal and offspring characteristic data included maternal risk factors, outcomes, delivery mode, and indication for suspected preeclampsia. Biochemical measurements to determine sFlt-1/PlGF ratio were performed using the BRAHMS/Kryptor sFlt-1/PlGF ratio immunoassays. Results were analyzed by area under receiver-operating characteristic curve. Preeclampsia occurred in 150 of 501 (30%) of symptomatic women with an sFlt-1/PlGF ratio determined before the time of diagnosis. Area under receiver-operating characteristic curve for diagnosis of early-onset preeclampsia within 1 and 4 weeks was 0.98 (95% CI, 0.96-1.00) and 0.95 (95% CI, 0.92-0.98), respectively. For late-onset preeclampsia, predictive performance within 1 and 4 weeks was lower 0.90 (95% CI, 0.85-0.94) and 0.85 (95% CI, 0.80-0.90), respectively. The optimal single sFlt-1/PlGF ratio threshold for all preeclampsia and late-onset preeclampsia within 1 and 4 weeks was 66. The negative and positive predictive values for ruling out and ruling in developing preeclampsia within 1 week were 96% and 70%, respectively. Conclusions The Kryptor sFlt-1/PlGF ratio is a useful clinical tool ruling out and in preeclampsia within 1 week. Prediction within 4 weeks is superior for early-onset preeclampsia. A single decision threshold of 66 is indicated for use in clinical routine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia / Receptor 1 de Fatores de Crescimento do Endotélio Vascular / Fator de Crescimento Placentário Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia / Receptor 1 de Fatores de Crescimento do Endotélio Vascular / Fator de Crescimento Placentário Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: J Am Heart Assoc Ano de publicação: 2021 Tipo de documento: Article