Your browser doesn't support javascript.
loading
A near-infrared light triggered fluormetric biosensor for sensitive detection of acetylcholinesterase activity based on NaErF4: 0.5 % Ho3+@NaYF4 upconversion nano-probe.
Zhao, Xu; Zhang, Ling; Yan, Xu; Zhang, Li; Lu, Yang; Pan, Jialin; Zhang, Meiling; Wang, Chenguang; Suo, Hui; Jia, Xiaoteng; Liu, Xiaomin; Lu, Geyu.
Afiliação
  • Zhao X; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Zhang L; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Yan X; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Zhang L; Department of Pulmonary and Critical Care Medicine, The First Hospital of Jilin University, Xinmin Street, Changchun, Jilin Province, 130021, China.
  • Lu Y; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Pan J; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Zhang M; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Wang C; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Suo H; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Jia X; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Liu X; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China. Electronic address: xiaominliu@jlu.edu.cn.
  • Lu G; State Key Laboratory on Integrated Optoelectronics, Jilin Key Laboratory on Advanced Gas Sensor, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China. Electronic address: lugy@jlu.edu.cn.
Talanta ; 235: 122784, 2021 Dec 01.
Article em En | MEDLINE | ID: mdl-34517642
ABSTRACT
Acetylcholinesterase (AChE), as an important neurotransmitter, is widely present in the peripheral and central nervous systems. The aberrant expression of AChE could cause diverse neurodegenerative diseases. Herein, we developed a facile and interference-free fluorimetric biosensing platform for highly sensitive AChE activity determination based on a NaErF4 0.5 % Ho3+@NaYF4 nano-probe. This nano-probe exhibits a unique property of emitting bright monochromic red (650 nm) upconversion (UC) emission under multiband (~808, ~980, and ~1530 nm) near-infrared (NIR) excitations. The principle of this detection relies on the quenching of the strong monochromic red UC emission by oxidization products of 3,3',5,5'-tetramethylbenzidine generated through AChE-modulated cascade reactions. This system shows a great sensing performance with a detection limit (LOD) of 0.0019 mU mL- 1 for AChE, as well as good specificity and stability. Furthermore, we validated the potential of the nano-probe in biological samples by determination of AChE in whole blood with a LOD of 0.0027 mU mL-1, indicating the potential application of our proposed platform for monitoring the progression of AChE-related disease.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acetilcolinesterase / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acetilcolinesterase / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2021 Tipo de documento: Article