Your browser doesn't support javascript.
loading
A membraneless self-powered photoelectrochemical biosensor based on Bi2S3/BiPO4 heterojunction photoanode coupling with redox cycling signal amplification strategy.
Cao, Jun-Tao; Lv, Jing-Lu; Liao, Xiao-Jing; Ma, Shu-Hui; Liu, Yan-Ming.
Afiliação
  • Cao JT; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. Electronic address: jtcao11@163.com.
  • Lv JL; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Liao XJ; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China.
  • Ma SH; Xinyang Central Hospital, Xinyang 464000, China.
  • Liu YM; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, Xinyang 464000, China. Electronic address: liuym9518@sina.com.
Biosens Bioelectron ; 195: 113651, 2022 Jan 01.
Article em En | MEDLINE | ID: mdl-34562789
ABSTRACT
The photoelectrochemical (PEC) self-powered system has attracted great attention in disease detection. The determination of a simple and efficient approach for disease-related biomarkers is highly interesting and appealing. Herein, an ingenious visible light-induced membraneless self-powered PEC biosensing platform was constructed, integrating a signal amplification strategy for ultrasensitive split-type PEC bioanalysis. The system was comprised of a Bi2S3/BiPO4 heterojunction photoanode and a platinum (Pt) cathode in a one compartment chamber. An alkaline phosphatase (ALP)-loaded sandwich immunoassay was used to generate the signal reporter ascorbic acid (AA) in a 96-well plate, and myoglobin (Myo) was used as a model protein. In the presence of AA, ferrocene (Fc), and Tris (2-carboxyethyl) phosphine (TCEP), the chemical-chemical redox cycling scheme was operated upon the initial oxidation of Fc by the holes in the Bi2S3/BiPO4 photoelectrode, and Fc was regenerated from Fc+ by AA. Subsequently, AA was regenerated by TCEP after its oxidation, and cycling was triggered. As a result, the proposed self-powered PEC sensing exhibited excellent performance with a wide linear range from 5.0 × 10-13 to 1.0 × 10-7 g/mL, and a low detection limit of 2.0 × 10-13 g/mL for Myo. This work provided a new design of a redox cycling strategy in the self-powered PEC biosensor, and showed an effective approach for the clinical diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2022 Tipo de documento: Article