Radiation dose to nurses, cardiologists, and patients during coronary angiography: a comparison of femoral and radial access.
Wilson-Stewart, Kelly S; Fontanarosa, Davide; Malacova, Eva; Trapp, Jamie V.
Afiliação
  • Wilson-Stewart KS; School of Chemistry and Physics, Faulty of Science and Engineering, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.
  • Fontanarosa D; Greenslopes Private Hospital, Ramsay Health Care, Newdegate Street, Greenslopes, Brisbane, QLD 4120 Australia.
  • Malacova E; School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.
  • Trapp JV; Centre for Biomedical Technologies (CBT), Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.
Eur J Cardiovasc Nurs ; 21(4): 325-331, 2022 06 02.
Article em En | MEDLINE | ID: mdl-34718509
ABSTRACT

BACKGROUND:

Exposure to radiation during fluoroscopically guided cardiac procedures is a cause for concern for both the patient and staff.

AIMS:

This study sought to compare the occupational and patient radiation dose during femoral and radially accessed invasive coronary angiography (CA). METHODS AND

RESULTS:

Occupational dose (µSv) was measured at the left temple of the cardiologist (n = 17), scrub (n = 27), and circulator nurse (n = 27) during 761 femoral and 671 radially accessed diagnostic coronary angiograms and percutaneous coronary intervention (PCI) procedures. Patient dose parameters of dose area product (DAP) (Gy.cm2) and air kerma (AK) (Gy) were also measured. Coronary angiography performed via the radial artery is associated with greater mean dose to the cardiologist, with the exception of procedures including only PCI. Results demonstrated that scrub nurses are exposed to higher mean doses than the cardiologist when using femoral access and similar doses during radial cases. Both AK and DAP were associated with a higher average dose for femoral PCI than radial, with DAP being significantly higher.

CONCLUSIONS:

Awareness of factors that increase the dose to staff and patients is vital to inform and improve practice. This study has demonstrated that access route during diagnostic CA and PCI influences both patient and staff dose. Radiation dose to in-room staff other than the fluoroscopic operator should be a focus of future research. In addition, all staff present during X-ray guided procedures should be provided with radiation education and adopt dose minimization strategies to reduce occupational exposures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intervenção Coronária Percutânea / Cardiologistas Limite: Humans Idioma: En Revista: Eur J Cardiovasc Nurs Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / ENFERMAGEM Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intervenção Coronária Percutânea / Cardiologistas Limite: Humans Idioma: En Revista: Eur J Cardiovasc Nurs Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / ENFERMAGEM Ano de publicação: 2022 Tipo de documento: Article