Your browser doesn't support javascript.
loading
Validation of Diagnostic Methods for European Foulbrood on Commercial Honey Bee Colonies in the United States.
Milbrath, Meghan O'Grady; Fowler, Peter Daniel; Abban, Samuel K; Lopez, Dawn; Evans, Jay D.
Afiliação
  • Milbrath MO; Department of Entomology, Michigan State University, 4090 N. College Road, Pollinator Performance Center, RM 100, Lansing, MI 48910, USA.
  • Fowler PD; Department of Comparative Medicine and Integrative Biology, Veterinary Medical Center, Michigan State University, 784 Wilson Road, Room G100, East Lansing, MI 48824, USA.
  • Abban SK; Bee Research Laboratory, USDA-Agricultural Research Service, B306 BARC-East Beltsville, MD 20705, USA.
  • Lopez D; Bee Research Laboratory, USDA-Agricultural Research Service, B306 BARC-East Beltsville, MD 20705, USA.
  • Evans JD; Bee Research Laboratory, USDA-Agricultural Research Service, B306 BARC-East Beltsville, MD 20705, USA.
J Insect Sci ; 21(6)2021 Nov 01.
Article em En | MEDLINE | ID: mdl-34723329
ABSTRACT
One of the most serious bacterial pathogens of Western honey bees (Apis mellifera Linnaeus [Hymenoptera Apidae]) is Melissococcus plutonius, the cause of the disease European foulbrood. Because European foulbrood is highly variable, with diverse outcomes at both the individual and colony levels, it is difficult to diagnose through visual inspection alone. Common lab diagnostic techniques include microscopic examination and molecular detection through PCR. In 2009, a lateral flow device was developed and validated for field diagnosis of European foulbrood. At the time, M. plutonius was thought to be genetically homogenous, but we have subsequently learned that this bacterium exists as multiple strains, including some strains that are classified as 'atypical' for which the lateral flow device is potentially less effective. These devices are increasingly used in the United States, though they have never been validated using strains from North America. It is essential to validate this device in multiple locations as different strains of M. plutonius circulate in different geographical regions. In this study, we validate the field use of the lateral flow device compared to microscopic examination and qPCR on larval samples from 78 commercial honey bee colonies in the United States with visual signs of infection. In this study, microscopic diagnosis was more sensitive than the lateral flow device (sensitivity = 97.40% and 89.47%, respectively), and we found no false positive results with the lateral flow device. We find high concurrence between the three diagnostic techniques, and all three methods are highly sensitive for diagnosing European foulbrood.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Bacterianas / Abelhas / Enterococcaceae Tipo de estudo: Diagnostic_studies Limite: Animals País/Região como assunto: America do norte Idioma: En Revista: J Insect Sci Assunto da revista: BIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções Bacterianas / Abelhas / Enterococcaceae Tipo de estudo: Diagnostic_studies Limite: Animals País/Região como assunto: America do norte Idioma: En Revista: J Insect Sci Assunto da revista: BIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos