The "Inside-outside" Sign.
Haridass, Shoban; Keshava, Shyamkumar N.
Afiliação
  • Haridass S; Department of Interventional Radiology, Division of Clinical Radiology, Christian Medical College, Vellore, Tamil Nadu, India.
  • Keshava SN; Department of Interventional Radiology, Division of Clinical Radiology, Christian Medical College, Vellore, Tamil Nadu, India.
J Clin Imaging Sci ; 11: 57, 2021.
Article em En | MEDLINE | ID: mdl-34754597
ABSTRACT
We describe a radiological sign, "inside-outside sign," observed during the cannulation of an expandable contrast-filled tubular structure in the human body. In this optical illusion, a catheter or guidewire appears to be outside the lumen when it is inside the lumen in reality. Knowing this rare optical illusion is essential to avoid mistaking it for a catheter or guidewire outside the lumen.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Imaging Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Índia