Your browser doesn't support javascript.
loading
Introduction of transcatheter aortic valve replacement technology increases overall aortic valve surgical volume: Evaluating the Florida experience.
Rogers, Michael P; Janjua, Haroon; Eguia, Emanuel; Lozonschi, Lucian; Kuo, Paul C.
Afiliação
  • Rogers MP; Department of Surgery, University of South Florida Morsani College of Medicine, Tampa, FL.
  • Janjua H; Department of Surgery, University of South Florida Morsani College of Medicine, Tampa, FL.
  • Eguia E; Department of Surgery, Loyola University Medical Center, Maywood, IL.
  • Lozonschi L; Division of Cardiothoracic Surgery and Transplantation, Department of Surgery, University of South Florida College of Medicine, Tampa, FL.
  • Kuo PC; Department of Surgery, University of South Florida Morsani College of Medicine, Tampa, FL. Electronic address: pckuo@usf.edu.
Surgery ; 171(3): 757-761, 2022 03.
Article em En | MEDLINE | ID: mdl-34953612
ABSTRACT

OBJECTIVE:

Transcatheter aortic valve replacement technology is increasingly used for aortic valve stenosis. We sought to evaluate the adoption of transcatheter aortic valve replacement technology with respect to overall surgical aortic valve replacement volume in Florida.

METHODS:

The 2010-2019 Florida Agency for Health Care Administration data set was queried. Difference-in-difference analysis was used to evaluate the impact of transcatheter aortic valve replacement on the total aortic valve surgical volume of transcatheter aortic valve replacement versus nonperforming hospitals. Length of stay and elements of charges were compared for the raw and 11 propensity matched data.

RESULTS:

A total of 46,032 surgical aortic valve procedures were performed at 88 hospitals. Transcatheter aortic valve replacement performing hospitals experienced a 21% increase in total aortic valve surgical volume. Length of stay was significantly less for patients undergoing transcatheter aortic valve replacement. Propensity matched transcatheter aortic valve replacement patients had less gross total charges.

CONCLUSION:

Introduction of transcatheter aortic valve replacement technology significantly increased overall surgical aortic valve volume and may be associated with less gross total hospital charges.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Surgery Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Substituição da Valva Aórtica Transcateter Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: Surgery Ano de publicação: 2022 Tipo de documento: Article