Your browser doesn't support javascript.
loading
Dynamic hybrid-phase computed tomography simulation in lung stereotactic body radiotherapy: A feasibility study.
Hwang, Jing-Min; Hung, Jing-Yin; Chang, You-Kang; Chang, Shih-Miao; Wang, Yu-Nong; Lin, Chun-Shu; Chang, Chiou-Shiung.
Afiliação
  • Hwang JM; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan; College of Medicine, Tzu Chi University, Hualien City, Taiwan.
  • Hung JY; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan.
  • Chang YK; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan; College of Medicine, Tzu Chi University, Hualien City, Taiwan.
  • Chang SM; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan.
  • Wang YN; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan.
  • Lin CS; Department of Radiation Oncology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.
  • Chang CS; Department of Radiation Oncology, Taipei Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taipei, Taiwan; Department of Radiation Oncology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan. Electronic address: et000417@gmail.com.
Med Dosim ; 47(2): 136-141, 2022.
Article em En | MEDLINE | ID: mdl-34987001
ABSTRACT
To assess the feasibility of dynamic hybrid-phase computed tomography (CTDHP) simulation when patients undergo lung stereotactic body radiation therapy (SBRT). Eighteen non-small-cell lung-cancer patients were immobilised in a stereotactic body frame with abdominal compression. All underwent dynamic hybrid-phase CT scans that were compared with cone-beam CT (CBCT). We also determined the internal target volume (ITV) and evaluated the following four metrics the "AND" function in the Boolean module of Eclipse, volume overlap (VO), Dice similarity coefficient (DSC), and dose-volume histogram. The average ITV values of 4DCTDHP and 3D-CBCT were respectively 12.82±10.42 and 14.6±12.18 cm3 (n=72, p<0.001), and the average ITV value of AND was 11.7±10.1 cm3. The average planning target volume (PTV) of 4DCTDHP and 3D-CBCT was 25.63±18.04 and 28.00±19.82 cm3 (n=72, p<0.001). The median AND difference between ITV and PTV was significant (p<0.01) and had a significantly linear distribution (R2=0.991 for ITV, R2=0.972 for PTV). The average VO of PTV was greater than that of ITV (0.81±0.096; 0.78±0.11). We also observed that the average DSC in PTV (0.83±0.066) was greater than that in ITV (0.81±0.084). The average results indicated that 97.9%±3.44 of ITVCBCT was covered by 95% of the prescribed dose. The average minimum, maximum and mean percentage doses of ITVCBCT were 87.9%±9.46, 107.3%±1.57, and 101.3%±1.12, respectively. This paper has demonstrated that dynamic hybrid-phase CT simulation for patients undergoing lung SBRT and also published evaluation metrics in scientific analysis. Our approach also has the advantage of adequate margin and fewer phases in CT simulation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Med Dosim Assunto da revista: RADIOTERAPIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Limite: Humans Idioma: En Revista: Med Dosim Assunto da revista: RADIOTERAPIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Taiwan
...