Your browser doesn't support javascript.
loading
Development of a new ultra-high-performance liquid chromatography-tandem mass spectrometry method for the determination of digoxin and digitoxin in plasma: Comparison with a clinical immunoassay.
Ballotari, Marco; Taus, Francesco; Tolle, Giulia; Danese, Elisa; Dorizzi, Romolo M; Tagliaro, Franco; Gottardo, Rossella.
Afiliação
  • Ballotari M; Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, Verona, Italy.
  • Taus F; Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, Verona, Italy.
  • Tolle G; Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, Verona, Italy.
  • Danese E; Section of Clinical Biochemistry, University of Verona, Verona, Italy.
  • Dorizzi RM; Clinical Pathology Unit, Hub Laboratory, Greater Area, Cesena, Italy.
  • Tagliaro F; Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, Verona, Italy.
  • Gottardo R; World-Class Research Center "Digital Biodesign and Personalized Healthcare", Sechenov First Moscow State Medical University, Moscow, Russia.
Electrophoresis ; 43(9-10): 1019-1026, 2022 05.
Article em En | MEDLINE | ID: mdl-35132652
Cardiac glycosides digoxin and digitoxin are used in therapy for the treatment of congestive heart failure. Moreover, these compounds can be responsible for intoxication cases caused by fortuitous ingestion of leaves of Digitalis. Due to the narrow therapeutic range of these drugs, therapeutic drug monitoring is recommended in the clinical practice. In this context, immunoassays-based methods are generally employed but digoxin- and digitoxin-like compounds can interfere with the analysis. The aim of this study was to develop and validate an original UPLC-MS/MS method for the determination of digoxin and digitoxin in plasma. The method shows adequate sensitivity and selectivity with acceptable matrix effects and very good linearity, accuracy, precision, and recovery. A simple liquid-liquid extraction procedure was used for sample clean-up. The method was applied for the analysis of n = 220 plasma samples collected in two different clinical chemistry laboratories and previously tested by the same immunoassay. The statistical comparison showed a relevant negative bias of the UPLC-MS/MS method versus the immunoassay. These results are consistent with an immunoassay overestimation of digoxin plasmatic levels due to cross-reaction events with endogenous digoxin-like substances.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Digitoxina / Digoxina Idioma: En Revista: Electrophoresis Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Digitoxina / Digoxina Idioma: En Revista: Electrophoresis Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha