Low-Cost Flexible Glass-Based pH Sensor via Cold Atmospheric Plasma Deposition.
Kasi, Venkat; Sedaghat, Sotoudeh; Alcaraz, Alejandro M; Maruthamuthu, Murali Kannan; Heredia-Rivera, Ulisses; Nejati, Sina; Nguyen, Juliane; Rahimi, Rahim.
Afiliação
  • Kasi V; School of Material Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
  • Sedaghat S; Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States.
  • Alcaraz AM; School of Material Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
  • Maruthamuthu MK; Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States.
  • Heredia-Rivera U; School of Material Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
  • Nejati S; Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, United States.
  • Nguyen J; Division of Pharmacoengineering and Molecular Pharmaceutics, Eshelman School of Pharmacy, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.
  • Rahimi R; School of Material Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
ACS Appl Mater Interfaces ; 14(7): 9697-9710, 2022 Feb 23.
Article em En | MEDLINE | ID: mdl-35142483
Many commercially available pH sensors are fabricated with a glass membrane as the sensing component because of several advantages of glass-based electrodes such as versatility, high accuracy, and excellent stability in various conditions. However, because of their bulkiness and poor mechanical properties, conventional glass-based sensors are not ideal for wearable or flexible applications. Here, we report for the first time the fabrication of a flexible glass-based pH sensor suitable for biomedical and environmental applications where flexibility and stability of the sensor are critical for long-term and real-time monitoring. The sensor was fabricated via a simple and facile approach using the cold atmospheric plasma technique in which a pH sensitive silica coating was deposited from a siloxane precursor onto a carbon electrode. In order to increase the sensitivity and stability of the sensor, we employed a postprocessing step which involves annealing of the silica coated electrode at elevated temperatures. This process was optimized to ensure that the crucial properties such as porosity and hydration functionality were balanced to obtain the best and most reliable sensitivity of the sensor. Our sensitivity test results indicated that these sensors exhibit excellent and stable sensitivity with a slope of about 48 mV/pH (r2 = 0.998) and selectivity across a pH range of 4 to 10 in the presence of various cations. The optimized sensor has shown stable sensitivity for a long period of time (30 h of immersion) and in different bending conditions. We demonstrate in this investigation that this flexible cost-effective pH sensor can withstand the sterilization process resulting from ultraviolet radiation and shows repeatable sensitivity with less than ±5 mV potential drift from the sensitivity values of the standard optimized sensor.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: ACS Appl Mater Interfaces Assunto da revista: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos