Delamination and dissection of arteriovenous grafts: A multicenter report of four cases.
Zhang, Xi; Hu, Bo; Xu, Yong; Lai, Qiquan; Chen, Ling; Gao, Xuejing; Tu, Bo; Chen, Bo; Zhou, Yu; Wan, Ziming.
Afiliação
  • Zhang X; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Hu B; Department of Nephrology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, China.
  • Xu Y; Department of Nephrology, The Third Xiangya Hospital of Central South University, Changsha, China.
  • Lai Q; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Chen L; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Gao X; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Tu B; Department of Ultrasonography, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Chen B; Department of Ultrasonography, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Zhou Y; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Wan Z; Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
J Vasc Access ; 24(6): 1507-1512, 2023 Nov.
Article em En | MEDLINE | ID: mdl-35164596
ABSTRACT
Arteriovenous (AV) grafts are an alternative vascular access for chronic hemodialysis. AV graft failure is often due to stenosis of the feeding artery, graft, or draining vein. We report four cases of AV graft dysfunction and failure rarely caused by graft delamination and dissection. Two males and two females aged 47-67 years had been on chronic hemodialysis. Ultrasound examination detected graft delamination and dissection between 1 and 33 months after Acuseal AV graft implantation. Two cases were successfully treated with stenting and partial graft replacement, respectively. False lumen volume reduction by fluid withdrawal failed to salvage the delaminated graft in one of the patients. The delamination and dissection of another case spontaneously resolved 5 months later. Graft delamination and dissection should be considered as a possible cause for AV graft dysfunction and failure. Stenting and graft replacement may be recommended to treat AV graft dissection and delamination.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Derivação Arteriovenosa Cirúrgica / Implante de Prótese Vascular Limite: Female / Humans / Male Idioma: En Revista: J Vasc Access Assunto da revista: ANGIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Derivação Arteriovenosa Cirúrgica / Implante de Prótese Vascular Limite: Female / Humans / Male Idioma: En Revista: J Vasc Access Assunto da revista: ANGIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China