Your browser doesn't support javascript.
loading
Development of an independent MU calculation software for radiotherapy treatments with stereotactic cones.
Campos, Guilherme Filipe Pinto; Souto, Ana Catarina Santos; Lencart, Joana Borges; Cunha, Luís Paulo Teixeira; Dias, Anabela Gregório.
Afiliação
  • Campos GFP; Department of Physics and Astronomy, Faculty of Sciences, University of Porto, Porto, Portugal.
  • Souto ACS; Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Centre (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.
  • Lencart JB; Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.
  • Cunha LPT; Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Centre (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.
  • Dias AG; Medical Physics Department, Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal.
J Appl Clin Med Phys ; 23(4): e13542, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35166027
PURPOSE: Development of an independent MU calculator (StereoCalc) with and without heterogeneity corrections for stereotactic treatments, in a Varian TrueBeam STx LINAC using stereotactic cones, with flattening filter-free photon energies. METHODS: Multiple depth curves and output factors were measured, following the dosimetry formalism for small fields proposed by the TRS-483. The developed StereoCalc imports and processes the beam data files and calculates the patient plans with and without heterogeneity correction. Validation of the developed software was carried out using phantoms. The accuracy of the StereoCalc software was verified in stereotactic patient plans. RESULTS: A maximum difference of 2.47% and 2.07% was obtained in the phantom validation tests with and without heterogeneity correction, respectively. The mean percentual difference of StereoCalc from cone dose calculation (CDC) in the clinical testing was 2.86% ±1.27% and 0.78% ±0.48% with and without heterogeneity correction, respectively. The largest differences found were 7.34% and 1.98%, respectively. CONCLUSIONS: The results obtained in this work show that the MU calculated with StereoCalc software is in good agreement with the values calculated by the treatment planning systems, both in static fields and arcs. We have also improved the software to consider heterogeneity corrections calculations. As expected, and as a major achievement of this work, some differences were observed when heterogeneities were considered. StereoCalc proved to be a powerful tool that can be integrated into the specific quality assurance program in a medical physics department for independent verification in stereotactic treatment with cones.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Portugal País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Portugal País de publicação: Estados Unidos