Impact of temperature changes to the adhesion strength of molar tubes: an in vitro study.
Palesik, Benedikta; Sileikyte, Kotryna; Griskevicius, Julius; Stonkus, Rimantas; Sidlauskas, Antanas; Lopatiene, Kristina.
Afiliação
  • Palesik B; Department of Orthodontics, Lithuanian University of Health Sciences, J. Luksos - Daumanto str. 6, 50106, Kaunas, Lithuania. Benedikta.palesik@stud.lsmu.lt.
  • Sileikyte K; Department of Biomechanical Engineering, VILNIUS TECH, J. Basanavicius Str. 28, Vilnius, Lithuania.
  • Griskevicius J; Department of Biomechanical Engineering, VILNIUS TECH, J. Basanavicius Str. 28, Vilnius, Lithuania.
  • Stonkus R; Department of Biomechanical Engineering, VILNIUS TECH, J. Basanavicius Str. 28, Vilnius, Lithuania.
  • Sidlauskas A; Department of Orthodontics, Lithuanian University of Health Sciences, J. Luksos - Daumanto str. 6, 50106, Kaunas, Lithuania.
  • Lopatiene K; Department of Orthodontics, Lithuanian University of Health Sciences, J. Luksos - Daumanto str. 6, 50106, Kaunas, Lithuania.
BMC Oral Health ; 22(1): 115, 2022 04 08.
Article em En | MEDLINE | ID: mdl-35395793
BACKGROUND: The main purpose of this was to determine study adhesion strength of molar tubes bonding with a composite adhesive after exposure to a sudden change in temperature (thermal cycles). METHODS: The study sample consisted of 40 recently extracted human first permanent molars, which were randomly divided into two groups of 20: group 1 was the experimental group (affected by thermal cycles), and group 2 was the control group. Molar tubes were bonded with a light-cure tube adhesive. The experimental group teeth were dipped 2,000 times in saline at 5 °C and at 55 °C. The control group were immersed in 37 °C saline. Molar tubes for both groups were removed with an adapted Mecmesim Multitesters 2.5-I, and the data were recorded with EMPEROR software. ANOVA was used to calculate and compare the results. RESULTS: In the experimental group of the teeth, the maximum force was obtained at 94.2 N and the lowest force was 19.69 N. In the control group of the teeth, the maximum force was obtained at 159.1 N and the lowest force was 28.1 N. In the experimental group, the mean debonding force (59.12 N) was statically significantly smaller than in the control group (79.88 N), p = 0.0345. The forces in the control group were by 1.35 times greater than those in the experimental group. CONCLUSIONS: The forces of the adhesion of molar tubes to the tooth surface were reduced after exposure to a sudden change in temperature (thermal cycles). The results were significantly different between the experimental group and the control group.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Braquetes Ortodônticos Limite: Humans Idioma: En Revista: BMC Oral Health Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Lituânia País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Braquetes Ortodônticos Limite: Humans Idioma: En Revista: BMC Oral Health Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Lituânia País de publicação: Reino Unido