Your browser doesn't support javascript.
loading
Particulate matter emissions during autopsies: a method to reduce exposure.
Dröge, Janis; Moussaoui, Ibrahim El; Klingelhöfer, Doris; Held, Hannelore; Groneberg, David A; Verhoff, Marcel A; Plenzig, Stefanie.
Afiliação
  • Dröge J; Institute of Occupational, Social, and Environmental Medicine, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany. droege@med.uni-frankfurt.de.
  • Moussaoui IE; Institute of Occupational, Social, and Environmental Medicine, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
  • Klingelhöfer D; Institute of Occupational, Social, and Environmental Medicine, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
  • Held H; Institute of Legal Medicine, Goethe University, University Hospital Frankfurt, Kennedyallee 104, 60596, Frankfurt am Main, Germany.
  • Groneberg DA; Institute of Occupational, Social, and Environmental Medicine, Goethe University Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
  • Verhoff MA; Institute of Legal Medicine, Goethe University, University Hospital Frankfurt, Kennedyallee 104, 60596, Frankfurt am Main, Germany.
  • Plenzig S; Institute of Legal Medicine, Goethe University, University Hospital Frankfurt, Kennedyallee 104, 60596, Frankfurt am Main, Germany.
Environ Sci Pollut Res Int ; 29(40): 60519-60530, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35420344
ABSTRACT
Particulate matter emitted during autopsies can serve as a vector for numerous viruses or bacteria and can lead to infections. Reducing the exposure of those particles in indoor working environments is, therefore, an important issue. To assess the health risk for employees in forensic medicine, we measure particulate matter in the ambient air during autopsies by using an aerosol spectrometer. The autopsies were performed with either an ordinary oscillating saw or an adapted saw with a suction unit. The particle emissions from both saws were compared to each other in order to evaluate whether a technical adaption leads to a particle reduction. Furthermore, the particle exposure reduction by wearing a face mask and variations in the background concentration in the room were analyzed. High particle concentrations were measured while using the ordinary saw. By using the adapted saw or wearing a face mask, the particle exposure could mostly be avoided. On the majority of the working days, an increase in the background concentration could be observed. Based on this knowledge, the use of a proper suction unit and wearing a face mask during autopsies is necessary. Besides, it is important to have sufficient ventilation in the room so that long-lasting high background concentrations can be prevented.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos Limite: Humans Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos Limite: Humans Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha