Your browser doesn't support javascript.
loading
Primary Repair of Posteriorly Located Anterior Skull Base Dural Defects Using Nonpenetrating Titanium Clips in Cranial Trauma.
Milton, Camille K; Andrews, Bethany J; Baker, Cordell M; O'Connor, Kyle P; Conner, Andrew K; Sughrue, Michael E; McKinney, Kibwei A; El Rassi, Edward T; Sanclement, Jose A; Glenn, Chad A.
Afiliação
  • Milton CK; Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Andrews BJ; Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Baker CM; Department of Neurosurgery, University of Utah School of Medicine, Salt Lake City, Utah, United States.
  • O'Connor KP; Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Conner AK; Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Sughrue ME; Department of Neurosurgery, Prince of Wales Hospital, Sydney, New South Wales, Australia.
  • McKinney KA; Department of Otorhinolaryngology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • El Rassi ET; Department of Otorhinolaryngology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Sanclement JA; Department of Otorhinolaryngology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
  • Glenn CA; Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, United States.
J Neurol Surg B Skull Base ; 83(2): 116-124, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35433178
Objective Primary repair of posteriorly located anterior skull base (ASB) dural defects following cranial trauma is made difficult by narrow operative corridors and adherent dura mater. Inadequate closure may result in continued cerebrospinal fluid (CSF) leak and infectious sequelae. Here, we report surgical outcomes following the use of nonpenetrating titanium microclips as an adjunctive repair technique in traumatic anterior skull base dural defects extending from the olfactory groove to the tuberculum sellae. Methods All trauma patients who underwent a bifrontal craniotomy from January 2013 to October 2019 were retrospectively reviewed. Patients with ASB defects located at posterior to the olfactory groove were analyzed. Patients with isolated frontal sinus fractures were excluded. All patients presented with CSF leak or radiographic signs of dural compromise. Patients were divided according to posterior extent of injury. Patient characteristics, imaging, surgical technique, and outcomes are reported. Results A total of 19 patients who underwent a bifrontal craniotomy for repair of posteriorly located ASB dural defects using nonpenetrating titanium microclips were included. Defects were divided by location: olfactory groove (10/19), planum sphenoidale (6/19), and tuberculum sellae (3/19). No patients demonstrated a postoperative CSF leak. No complications related to the microclip technique was observed. Clip artifact did not compromise postoperative imaging interpretation. Conclusion Primary repair of posteriorly located ASB dural defects is challenging due to narrow working angles and thin dura mater. Use of nonpenetrating titanium microclips for primary repair of posteriorly located dural defects is a reasonable adjunctive repair technique and was associated with no postoperative CSF leaks in this cohort.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurol Surg B Skull Base Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurol Surg B Skull Base Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Alemanha