Your browser doesn't support javascript.
loading
Investigation of Some Gaseous and Trace Metal Emissions With Their Emission Factors From Various Brands of Mosquito Coils Used in Nigeria.
Elehinafe, Francis B; Okedere, Oyetunji B; Oladimeji, Temitayo E; Anabui, Sarah O.
Afiliação
  • Elehinafe FB; Department of Chemical Engineering, College of Engineering, Covenant University, Ota, Ogun State, Nigeria.
  • Okedere OB; Department of Chemical Engineering, Faculty of Engineering, Osun State University, Osogbo, Osun State, Nigeria.
  • Oladimeji TE; Department of Chemical Engineering, College of Engineering, Covenant University, Ota, Ogun State, Nigeria.
  • Anabui SO; Department of Chemical Engineering, College of Engineering, Covenant University, Ota, Ogun State, Nigeria.
Environ Health Insights ; 16: 11786302221091741, 2022.
Article em En | MEDLINE | ID: mdl-35450271
ABSTRACT
Mosquito coils of various brands are frequently burnt in indoor environments to drive away mosquitoes-the vector for malaria parasite in regions where the disease is endemic. Emissions from the coils could be a source of indoor air pollution. In this study, various brands of mosquito coils obtained from retail shops in Lagos, Nigeria were burnt in an environmental test box with a view to characterizing carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO2) in the gaseous emissions as well as elemental concentrations of the ash. Emission characterization achieved with the RAS1700 bio-gas analyzer while AAS was adopted for elemental analysis of the mosquito coil ashes. The emission factor of CO, NO and NO2 from the coil samples ranged between 0.00138 to 0.26277 µg/m3, 0.0002 to 0.00454 µg/m3, and 0.000074 to 0.00714 µg/m3, respectively. These values were found to be lower than permissible indoor levels recommended by NIOSH. The range of concentrations of Pb, Zn, Cd, Cr, Cu, As, Hg, Fe in the coil ashes from all the brands were 0.02 to 0.04 mg/g, 0.011 to 0.02 mg/g, 0.001 to 0.003 mg/g, 0.004 to 0.008 mg/g, 0.004 to 0.006 mg/g, 0.0001 to 0.0004 mg/g, 0.001 to 0.003 mg/g, and 0.124 to 0.14 mg/g, respectively. Although, the concentrations of the pollutants obtained in this study are within the recommended limits, prolong exposure could trigger chronic disease conditions. Adequate ventilation of indoor environments or utilization of mosquito nets in place of coils could be considered.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Environ Health Insights Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Nigéria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Environ Health Insights Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Nigéria