Your browser doesn't support javascript.
loading
Sensitive determination of uranium using ß-cyclodextrin modified graphene oxide and X-ray fluorescence techniques: EDXRF and TXRF.
Kocot, Karina; Pytlakowska, Katarzyna; Talik, Ewa; Krafft, Christoph; Sitko, Rafal.
Afiliação
  • Kocot K; Institute of Chemistry, University of Silesia, Szkolna 9, 40-006, Katowice, Poland. Electronic address: karina.kocot@us.edu.pl.
  • Pytlakowska K; Institute of Chemistry, University of Silesia, Szkolna 9, 40-006, Katowice, Poland.
  • Talik E; Institute of Physics, University of Silesia, 75 Pulku Piechoty, 41-500, Chorzów, Poland.
  • Krafft C; Leibniz Institute of Photonic Technology, Member of Research Alliance "Health Technologies", Albert-Einstein-Straße 9, Jena, 07745, Germany.
  • Sitko R; Institute of Chemistry, University of Silesia, Szkolna 9, 40-006, Katowice, Poland.
Talanta ; 246: 123501, 2022 Aug 15.
Article em En | MEDLINE | ID: mdl-35525057
ABSTRACT
ß-cyclodextrin/graphene oxide (GO-ß-CD) was applied for dispersive micro-solid phase extraction (DMSPE) of uranyl ions (UO22+) from water samples and their determination by energy-dispersive (EDXRF) and total-reflection X-ray fluorescence spectrometry (TXRF). The structure of GO-ß-CD was characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, and Raman spectroscopy. The results of batch adsorption experiment indicate that the maximum recoveries for UO22+ ions are observed at pH 4.5. The Langmuir isotherm model fits the adsorption data, which stands for the chemisorption mechanism. The obtained adsorption capacity of 87.7 mg g-1 indicates a great potential of the synthesized adsorbent in the UO22+ ions preconcentration. The GO-ß-CD exhibits high resistance to high ionic strength (up to 2 mol L-1), indicating that high salinity samples can be treated with the evaluated preconcentration procedure. The obtained limit of detection values were 0.40 µg L-1 for the EDXRF and only 0.014 µg L-1 for TXRF analysis. The accuracy of the method was verified by analyzing certified reference material (spring water NIST-SRM 1640a) and spiked water samples (mineral, lake, river, and artificial sea water).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urânio / Beta-Ciclodextrinas / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2022 Tipo de documento: Article País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urânio / Beta-Ciclodextrinas / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2022 Tipo de documento: Article País de publicação: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS