Your browser doesn't support javascript.
loading
Selection of an impedance- or magnetic field-based electro-anatomical mapping platform does not affect outcomes of outflow tract premature ventricular complex manual ablation.
Ábrahám, Pál; Ambrus, Mercédesz; Herczeg, Szilvia; Szegedi, Nándor; Nagy, Klaudia Vivien; Salló, Zoltán; Perge, Péter; Osztheimer, István; Széplaki, Gábor; Tahin, Tamás; Merkely, Béla; Gellér, László.
Afiliação
  • Ábrahám P; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary. palabrah@gmail.com.
  • Ambrus M; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Herczeg S; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Szegedi N; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Nagy KV; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Salló Z; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Perge P; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Osztheimer I; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Széplaki G; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
  • Tahin T; Heart and Vascular Centre, Mater Private Hospital, Eccles St, Dublin 7, D07 WKW8, Ireland.
  • Merkely B; Royal College of Surgeons in Ireland, 23 St Stephen's Green, Dublin 2, D02 YN77, Ireland.
  • Gellér L; Semmelweis University Heart and Vascular Centre, Városmajor u. 68, Budapest, 1122, Hungary.
Heart Vessels ; 37(10): 1769-1775, 2022 Oct.
Article em En | MEDLINE | ID: mdl-35554635
Comparative data are virtually missing about the performance of different electro-anatomical mapping (EAM) system platforms on outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with manual ablation catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of impedance-based (IMP) and magnetic field-based (MAG) EAM platforms in manual OT PVC ablation. Single-centre, propensity score matched data of 39-39 patients ablated for OT PVCs in 2015-17 with IMP or MAG platforms were analysed. Acute success rate, peri-procedural complications, post-ablation daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate was similar in the IMP and MAG group (77 vs. 82%, p = 0.78). There was a single case of femoral pseudo-aneurysm and no cardiac tamponade occurred. PVC burden fell significantly from baseline 24.0% [15.0-30.0%] to 3.3% [0.25-10.5%] (p < 0.001) post-ablation, with no difference between EAM platforms (IMP: 2.6% [0.5-12.0%] vs. MAG: 4.0% [2.0-6.5%]; p = 0.60). There was no significant difference in recurrence-free survival of the intention-to-treat cohort of the IMP and MAG groups (54 vs. 60%, p = 0.82, respectively) during 12 months of follow-up. Ablation with the aid of both impedance- and magnetic field-based EAM platforms can considerably reduce OT PVC burden and give similar acute- and long-term freedom from arrhythmia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Complexos Ventriculares Prematuros Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Hungria País de publicação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Complexos Ventriculares Prematuros Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Heart Vessels Assunto da revista: CARDIOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Hungria País de publicação: Japão