Your browser doesn't support javascript.
loading
A novel metal-organic frameworks composite-based label-free point-of-care quartz crystal microbalance aptasensing platform for tetracycline detection.
Yang, Yukun; Yang, Lanqing; Ma, Yuanyuan; Wang, Xiaomin; Zhang, Jinhua; Bai, Baoqing; Yu, Ligang; Guo, Caixia; Zhang, Fuyuan; Qin, Shu.
Afiliação
  • Yang Y; School of Life Science, Shanxi University, Taiyuan 030006, China. Electronic address: yangyukun@sxu.edu.cn.
  • Yang L; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Ma Y; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Wang X; Institute of Pharmaceutical and Food Engineering, Shanxi University of Chinese Medicine, Yuci 030619, China. Electronic address: wangxiaomin061@126.com.
  • Zhang J; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Bai B; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Yu L; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Guo C; School of Life Science, Shanxi University, Taiyuan 030006, China.
  • Zhang F; College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China. Electronic address: zhang.fuyuan@hotmail.com.
  • Qin S; Shanxi Center for Testing of Functional Agro-Products, Shanxi Agricultural University, Taiyuan 030031, China.
Food Chem ; 392: 133302, 2022 Oct 30.
Article em En | MEDLINE | ID: mdl-35636180
A novel label-free point-of-care quartz crystal microbalance (QCM) aptasensing platform based on metal-organic frameworks (MOFs) and gold nanoparticles (AuNPs) was fabricated for tetracycline (TC) detection. MOFs (HKUST-1) and AuNPs were modified onto the sensing interface of QCM sensor to enhance the sensing performance of the QCM aptasensor. TC aptamer with sulfhydryl group was fixed through Au-S bond. The recognition performance of the aptasensor was predicted and verified by the computer simulation. At the optimal conditions, the frequency change of the sensor was adopted for quantitative detection of TC. The prepared QCM aptasensor exhibited a wide linear range from 1 × 10-10 g mL-1 to 1 × 10-5 g mL-1 with low limit of detection (0.8 × 10-11 g mL-1). High sensitivity, good selectivity, acceptable recoveries (87.6-91.4%) in real samples were obtained. For the first time, MOFs were utilized in the construction of QCM aptasensing platform, providing a promising application way of MOFs in the QCM sensing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Food Chem Ano de publicação: 2022 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Food Chem Ano de publicação: 2022 Tipo de documento: Article País de publicação: Reino Unido