Your browser doesn't support javascript.
loading
Investigation of the dosimetric parameters of 125I BEBIG IsoSeed® I25.S06 source: GATE 8.2 Monte Carlo code.
Ait-Mlouk, L; Khalis, M; Asnaoui, H; Ouabi, H; Elboukhari, S.
Afiliação
  • Ait-Mlouk L; Moulay Ismail University, Faculty of Sciences, Department of Physics, Meknès, Morocco. Electronic address: mloukylahcen@gmail.com.
  • Khalis M; Moulay Ismail University, Faculty of Sciences, Department of Physics, Meknès, Morocco. Electronic address: m.khalis2011@gmail.com.
  • Asnaoui H; Moulay Ismail University, Faculty of Sciences, Department of Physics, Meknès, Morocco. Electronic address: hassan.asnaoui@gmail.com.
  • Ouabi H; Oncology Centre Al Azhar, Rabat, Morocco. Electronic address: ouabi@yahoo.fr.
  • Elboukhari S; Moulay Ismail University, Faculty of Sciences, Department of Chemistry, Meknès, Morocco. Electronic address: saidhorizon@gmail.com.
Appl Radiat Isot ; 186: 110294, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35660985
ABSTRACT
Permanent implantation of the iodine-125 brachytherapy sources is an irradiation technique for the treatment of the localized cancer. As described by the American Association of Physicists in Medicine (AAPM) Task group 43 (TG-43U1), it is crucial to determine the dose distribution around the brachytherapy seed before its effective clinical practice or even before releasing the sources for the treatment. In the present work, according to TG-43U1 report, the dosimetric parameters of BEBIG iodine-125 Low Dose Rate brachytherapy IsoSeed® I25.S06 source model was investigated. To perform the dose calculations, we have used GEANT4 Application for Emission Tomography (GATE) Monte Carlo simulations. Interesting results have been found. In particular, the dosimetric quantities like the radial dose function gL(r), the anisotropy function F(r,θ) and the dose rate constant Λ have been obtained. In addition, our data are in good agreement with the previous published works. It is also remarked that, GATE Monte Carlo code reproduces accurate dosimetric parameters results.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braquiterapia / Radioisótopos do Iodo Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braquiterapia / Radioisótopos do Iodo Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2022 Tipo de documento: Article